Pymeter PY-20THHumidistat Temperature Humidity Controller Reptile Mushroom Greenhouse Thermostat Dual Controlled Outlets Heater Fridge Humidifier Dehumidifier

Pymeter PY-20THHumidistat Temperature Humidity Controller Reptile Mushroom Greenhouse Thermostat Dual Controlled Outlets Heater Fridge Humidifier Dehumidifier

$29.99
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

Able to read & control both temperature and humidity, Pymeter is an easy-to-use device with dual outlets and enhanced functions. It also supports High and Low Temperature/Humidity Alarm, making it safe and reliable. Brand Pymeter Item Dimensions LxWxH 8.26 x 2.16 x 1.57 inches (21 x 5.5 x 4 cm) Controller Type ON & OFF Controller Special Feature Programmable Color White Specific Uses For Product Heater/Cooler & Humidifier/Dehumidifier null Heater/Cooler & Humidifier/Dehumidifier Included Components Temperature and Humidity ALL IN ONE Sensor Item Weight 1 Pounds (0.45 kg) Shape Rectangular Display Type LCD Control Type Button Control Backlight Yes Wattage 1200 watts Product Dimensions 8.26 x 2.16 x 1.57 inches (21 x 5.5 x 4 cm) Item Weight 1 pounds (0.45 kg) Manufacturer Pymeter Item model number PY-20TH Features: Dual Outlets: Outlet 1 controls Heating or Cooling, outlet 2 controls Humidification or Dehumidification. All In One Sensor: Able to read & control both of temperature and humidity. Easy to Use: Each outlet has independent temperature/humidity controlled switch and it intelligently identify heating/cooling and humidification/dehumidification mode via ON & OFF set-point, it is very easy and flexible to keep target at desired temperature/humidity range. Safe and Reliable: Support High and Low Temperature/Humidity Alarm. Enhanced Functions: Power-Off Memory; Power-On Delay; Temperature/Humidity Calibration. 1. How Pymeter control Temperature? Temperature controller is actual Heating/Cooling controller, thus MUST SET ON-Temp to turn ON Heating/Cooling, and MUST SET OFF-Temp to turn OFF Heating/Cooling. Heating starts at LOW Temp [ON-Temp(1tN)], stops at HIGH Temp [OFF-Temp(1tF)], thus for heating MUST SET 1tN LESS than 1tF; In heating mode, 1tN is the minimum temp you allow, 1tF is the maximum temp you allow. Cooling starts at HIGH Temp [ON-Temp(1tN)], stops at LOW Temp [OFF-Temp(1tF)], thus for cooling MUST SET 1tN GREATER than 1tF. In cooling mode, 1tN is the maximum temp you allow, 1tF is the minimum temp you allow. 2. How Pymeter control Humidity? Humidification starts at LOW Humidity [ON-Humidity(2hn)], stops at HIGH Humidity [OFF-Humidity(2hF)], thus for humidification MUST SET 2hn LESS than 2hF; In humidification mode, 2hn is the minimum humidity you allow, 2hF is the maximum humidity you allow. Dehumidification starts at HIGH Humidity [ON-Humidity(2hn)], stops at LOW Humidity [OFF-Humidity(2hF)], thus for dehumidification MUST SET 2hn GREATER than 2hF. In dehumidification mode, 2hn is the maximum humidity you allow, 2hF is the minimum humidity you allow. INCLUDES:  1 x Humidistat Temperature Humidity Controller

Show More Show Less