Power Conditioner, Voltage Regulator, & Battery Backup UPS For Thermo Fisher Scientific / Applied Biosystems 7900HT Fast Real-Time PCR System

Power Conditioner, Voltage Regulator, & Battery Backup UPS For Thermo Fisher Scientific / Applied Biosystems 7900HT Fast Real-Time PCR System

$9,044.99

The online (double conversion) pure sine wave lab safety battery backup uninterruptible power supply (UPS) and power conditioner with surge protector automatically provides defense against power problems that may impact the performance of the Thermo Fisher Scientific / Applied Biosystems 7900HT Fast Real-Time PCR System. Give your lab instruments longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance. Much more than a battery in a box, every Battery Backup Power, Inc. system doubles as a power conditioner, actively correcting voltage issues left unresolved by the power company or created by other power hungry electronics in your lab environment (laser printers, HVAC systems, refrigeration equipment, etc.).This is a plug and play system. An existing or electrician pre-wired 208 Volt, NEMA L6-30R (Receptacle) on a 30 amp breaker in your laboratory is all you need. Rolling casters allow you to easily move the entire unit from room to room for use wherever there is a 208 Volt, NEMA L6-30R (Receptacle) available. This system allows for 120 VAC equipment such as computers to be plugged into the top row of outlets on the PDU and 208-240 VAC equipment such as lab instruments and pumps to be plugged into the bottom row of outlets on the PDU.  User Guides:-Battery Backup Power 6KVA-10KVA Tower UPS User Guide-Battery Backup Power 6KVA-10KVA External Battery Pack Tower UPS User Guide-Battery Backup Power 6KVA-10KVA Tower UPS Parallel System Installation Guide-Battery Backup Power 6KVA-10KVA Tower UPS Transformer User Guide Spec Sheet/Cut Sheet:-BBP 4.5-20KVA Tower DSP Series Specification Sheet.pdf Complete 5 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Heavy Duty Isolation Transformer, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology. Multiple Backup Time Options: Model Number: Description (Under Battery Options Drop Down): Approximate Backup Time At Full Load: BBP-AR-6000-PSW-ONL UPS With Internal Batteries Only (20 Batteries, 12 Volts, 9 Amp Hours Each) 15 Minutes BBP-AR-6000-PSW-ONL-WEBPWC UPS Plus 1 Extra External Battery Pack (80 Batteries, 12 Volts, 9 Amp Hours Each) 1 Hour 0 Minutes BBP-AR-6000-PSW-ONL-W2EBPWC UPS Plus 2 Extra External Battery Packs (140 Batteries, 12 Volts, 9 Amp Hours Each) 1 Hour 45 Minutes BBP-AR-6000-PSW-ONL-W3EBPWC UPS Plus 3 Extra External Battery Packs (200 Batteries, 12 Volts, 9 Amp Hours Each) 2 Hours 31 Minutes BBP-AR-6000-PSW-ONL-W4EBPWC UPS Plus 4 Extra External Battery Packs (260 Batteries, 12 Volts, 9 Amp Hours Each) 3 Hours 16 Minutes BBP-AR-6000-PSW-ONL-W5EBPWC UPS Plus 5 Extra External Battery Packs (320 Batteries, 12 Volts, 9 Amp Hours Each) 4 Hours 1 Minutes  *Note: The 6 kVA model now has 9 amp hour batteries installed instead pf the standard 7 amp hour batteries. This increases battery capacity and backup time by approximately 22%. 6000 VA (6 kVA) / 5,400 Watt (5.4 kW) N+1 And Parallel Operation Up To 24 kVA (4 Units In Series) Energy Efficient/High Efficiency UPS Mode LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time Tower With Casters Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source) Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS) Constant Voltage Regulation (±1%) Constant Frequency Regulation (±1 or ±3% Selectable) Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration >0.99 Input Power Factor / 0.9 Output Power Factor (Line Mode) / High Efficiency Mode For Superior Efficiency And Power Savings INPUT: NEMA L6-30P (Plug) 208, 220, 230, or 240 Volts Single Phase, 30 Amps Minimum OUTPUT: Dual Voltage Multiple Receptacle Box 8x NEMA 5-15/20R (Receptacles, 120 VAC) Fits Either NEMA 5-15P (Plug) Or NEMA 5-20P (Plug) 1x NEMA L5-30R (Receptacle, Twist Lock, 120 VAC) Fits NEMA L5-30P (Plug, Twist Lock) 1x NEMA L6-15R (Receptacle, Twist Lock, 240 VAC) Fits NEMA L6-15P (Plug, Twist Lock) 1x NEMA L6-20R (Receptacle, Twist Lock, 240 VAC) Fits NEMA L6-20P (Plug, Twist Lock) 4x NEMA 6-15/20R (Receptacles, 240 VAC) Fits Either NEMA 6-15P (Plug) Or NEMA 6-20P (Plug) 1x NEMA L6-30R (Receptacle, Twist Lock, 240 VAC) Fits NEMA L6-30P (Plug, Twist Lock) UPS Weight (Excluding Optional External Battery Packs): 264 lbs. Dimensions (Inches): 11.4 X 29.5 X 25.4 (W x H x D) Operating Temperature: 32°-104° F Operating Humidity: 20%~95%, Non-Condensing Operating Elevation: 3,280 Feet Without De-Rating  Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping) cTUVus, cULus, and FCC Certified Includes Software For Windows Monitoring & Configuration   Replacement Batteries:-Leoch DJW12-9.0 (Lead Acid), Leoch LP12-9.0 (Lead Acid), Betta Batteries 6-HCNFJ-7.2 (Lead Crystal), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)  Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com.   

Show More Show Less

Price History

$6,699.99 $9,044.99 (+$2,345)