Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner For BD Biosciences LSR II Flow Cytometer

Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner For BD Biosciences LSR II Flow Cytometer

$10,799.99

The battery backup uninterruptible power supply (UPS) and power conditioner for BD Biosciences LSR II Flow Cytometer with surge protector automatically provides defense against power problems. Give your lab instruments longer life while protecting them from harmful dirty power problems that may otherwise damage or degrade their performance. Much more than a battery in a box, every Battery Backup Power, Inc. system doubles as a power conditioner, actively correcting voltage issues left unresolved by the power company or created by other power hungry electronics in your lab environment (laser printers, HVAC systems, refrigeration equipment, etc.). Complete 5 Tier Laboratory Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Heavy Duty Isolation Transformer, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology. Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com.  6,000 VA (6 kVA) / 4,200 Watt (4.2 kW) Maximum Uninterruptible Power Supply 208-240 Volt Single Phase Input / 120 Volt Or 240 Volt Single Phase Output Built In Isolation Transformer To Suppress Electrical Noise For Sensitive Devices As Well As Protect Users From Faulty Equipment Tower Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay Accepts Generator Power (Direct or on Automatic Transfer Switch) Constant Voltage Regulation Constant Frequency Regulation Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries Optional Extended Warranty: 6 Years On Electronics And 3 Year Warranty On Batteries Industrial Grade For Laboratory Use 0.7 Power Factor 20 Batteries, 12 Volt, 7.2 Amp Hour Rating Each 208-240 Volt Single Phase Input, 30 Amp Circuit Required Typical Installation Options: Branch Circuit PDU: 3 NEMA 5-20 receptacles (lab instrument) and 3 NEMA 5-15 receptacles (computer, monitor, and workstation) Estimated Run Time Based On Battery Configuration: 17 Minutes 38 Seconds UPS Only 35 Minutes 17 Seconds UPS Plus 1 Battery Cabinet 52 Minutes 55 Seconds UPS Plus 2 Battery Cabinets BBP-6000-PSW-ONL-BDBIOSCIENCES-LSRII Configurable Output 120V/240V For Use With BD Biosciences LSR II Flow Cytometer Including The Following Components: Cytometer (including Coherent 488-nm Sapphire DPSS laser, Coherent 405-nm Vioflame laser, and JDS Uniphase 633-nm HeNe laser) Lightwave 355-nm Xcyte laser or Kimmon 325-nm HeCd laser Computer system (including workstation, monitor, and printer) Includes UPSMON Plus For Windows Monitoring & Configuration Software: Download Here Add A Power Failure Cellular Text/SMS Alert Module Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders) User Guide:https://cdn.shopify.com/s/files/1/0690/5525/files/BBP-6000-PSW-ONL_User_Guide.pdf?6489480182054981154 Replacement Batteries:-Type: 12 Volt 7.2 Amp Hour Batteries-Make & Model Number: Yuasa NPW36-12 12V 7.2Ah or Equivalent-Lowest Cost: $24.99 Each Plus Shipping On Amazonhttp://www.amazon.com/Yuasa-NPW36-12-7-2Ah-Replacement-Battery/dp/B00C811ZOY/ Backup time has been optimized for facilities that are equipped with an emergency generator system with an automatic transfer switch (ATS). Generator mode may be enabled from the UPS menu. How The University of Nevada, Reno Keeps Its Lab Running When The Power Fails How Providence Medical Center Gets Excellent Lab Results Every Time   How Hematology Oncology Consultants Protects Its Life Saving Refrigerated Drugs The Uninterruptible Power Supply (UPS) Inverter Capacity XXXX VA / XXXX Watts Determines How Many Watts Can Be Used From The UPS (How Large Of An Electrical Load). This Stays Constant Even If Extra Batteries Are Added. For Example, A 600 Watt UPS Can Run 10x 60 Watt Light Bulbs. Extra Batteries Or External Battery Packs/Cabinets Increase Run Time (The Time Electronics Can Be Run On Battery Power). Extra Batteries Do Not Increase The Inverter Capacity (How Many Watts Can Be Used From The UPS). For Example, A 600 Watt UPS Can Still Only Run 10x 60 Watt Light Bulbs, But With Extra Batteries, It Can Run Those Light Bulbs Much Longer. Get an estimation of how long your electronics will run on backup battery power with this unit during a power outage. Write down the Power Factor, Number of Batteries, Voltage of Batteries, and Amp Hour Rating from above, then click here to go to our uninterruptible power supply (UPS) backup run time calculator.   

Show More Show Less

Price History

$7,999.99 $10,799.99 (+$2,800)