050-160-060-005 PAT Hirschmann DS160 Console
PAT Hirschmann DS 160 Console No re-calibration Displays actual and allowable load, boom length,boom angle, and load radius Uses existing boom components Integrated bar graph provides a quick reference ofthe cranes utilization User-friendly console and setup Meets SAE and ANSI B-30.5 standards DS160 Console Operators & Service Manuals: Hirschmann DS160 General Information The PAT Hirschmann DS 160 Load Moment Indicator (LMI) DS 160 console has been designed to provide the crane operator with the essential information required to operate the machine within its design parameters. The LMI provides the operator with information regarding the length and angle of the boom, working radius, rated load and the total calculated weight being lifted by the crane. The DS 160 LMI basically consists of a central microprocessor unit, operator’s console, length and angle sensor, pressure transducer sensor, and anti-two block switches. The system operates on the principle of reference/r