Boiler Oxygen Scavenger - 5 to 55 Gallons
Boiler Oxygen Scavenger What is ChemWorld 1537?ChemWorld 1537 is the most common oxygen scavenger in boiler water chemistry is sodium sulfite. This product comes in various ph and concentrations. How does an Oxygen Scavenger work?Oxygen Scavengers remove the dissolved oxygen in the makeup/feed water. Residuals of the oxygen scavenger should be maintained in the boiler water to protect against the metals from corrosion. Any residuals of sulfite mean there is no dissolved oxygen is present in the boiler water. Extra sulfite residual provides added protection in case of upset conditions. Where do should the Oxygen Scavenger be feed?Ideally, this product should be fed the center of the deaerator storage side or feed water tank with a chemical injection quill.What product is recommended for removing dissolved oxygen?ChemWorld 1537 is a neutral pH sulfite (7.0 pH) solution which, when added to boiler feedwater, removes dissolved oxygen. An oxygen scavenger contains a catalyst that increases