BENTLY NEVADA 3300/48-02-01-00-00 Case Expansion Monitor
Description The 3300/48-02-01-00-00 Case Expansion Monitor uses two DC Linear Variable Differential Transformers (LVDTs) to track casing growth in relation to the machine foundation. It calculates the difference between the two transducers and sets two digitally adjustable alarm setpoints based on this measurement. The monitor provides two display modes: one for independent display of each case expansion channel or a differential measurement between the two channels. Alarms are available only when the monitor operates in Differential mode. 3300/48-AXX-BXX-CXX-DXX Configuration Options A: Full-scale Range Option 0: 0 - 25 mm (Requires 1 in. LVDT) B: Transducer Input Option 0: 1 in. LVDT (9 mV/mil) C: Alarm Relay Option 0: No Relays D: Agency Approval Option 0: Not required