
CONTEC TLC5000 ECG Monitor
CONTEC's Dynamic ECG System boasts a 12-lead design that meets international standards, enabling seamless 24-hour monitoring and interpretation of ECG patterns with the help of its compatible PC software. This cutting-edge innovation is ideal for use in both medical facilities and community environments.Function 1) The recorder can real-time store ECG data for 24-hour. 2) Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work. 3) Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion. 4) With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms. 5) Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel. 6) Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis. 7) All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. 8) With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudo fusion” and “Ventricular asynchronous pacing”, etc. 9) Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function. 10) With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability. 11) One-key print, convenient and fast to print the reports. 12) Perfect case management function. 13) When analyzing an abnormal ST segment, the advanced ST segment analysis and total load of myocardial ischemia can be used to evaluate both the entire event and individual instances. This method allows doctors to make comprehensive judgments regarding myocardial ischemia. 14) Using the unique "Sleep breath pause syndrome" analysis function, the CONTEC Dynamic ECG System TLC5000 can accurately predict the risk of sleep breath pause. 15) The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function. 16) T-Wave alternation is a critical factor in predicting malignant arrhythmia and sudden cardiac death. 17) With the addition of QTD, VCG, VLP, and TVCG analysis modules, the analysis report becomes even more valuable due to objective and scientific measurements and data. Performance Lead: standard 12-lead Record time: 24-hour Power supply: two “AA” batteries Interface: USB2.0 Sampling accuracy: 24bit Sampling frequency: 250Hz Dynamic range: 10mV Input impedance: ≥10MΩ CMR: ≥60dB Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10% Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period. System noise: ≤50µVp-p Multichannel crosstalk: ≤0.2mV Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz. Minimum measure signal: 50 µV With the function in the presence of pacemaker pulses Timing accuracy: the overall error during 24h shall not exceed 30s.Accessories Lead cable (1 set) ECG electrode (1 bag) USB cable (1) Bag (1) User manual (1)Physical CharacteristicsDimension: 111mm(L) × 61mm(W) × 25mm(H) Weight: about 105g(without batteries)