
CONTEC MS200 NIBP Simulator Blood Pressure Monitor Accuracy Simulation Test
Introduction It is a multi - purpose test device for testing NIBP Monitor adopted Oscillometry. Concise and elegant in appearance, easy and convenient to operate, and it can generate the pressure up to 400mmHg (53.3 kPa) by the built-in air pump. With the functions of dynamic BP simulation under several conditions, static pressure calibration, automatic leak test and over-pressure relief test, which can quickly and accurately analyze each performance of NIBP Monitor. Functions 1)Pressure leak test 2)Over-pressure relief test 3)BP simulation under standard condition 4)BP simulation under patient condition 5)BP simulation under arrhythmia condition 6)BP simulation under respiratory interference condition 7)BP simulation of neonate 8)Wrist BP simulation 9)User-defined BP simulation 10)System setting function. 11)The parameters set can be stored. 12)ON/OFF function 13)Dynamic BP simulation Performance BP simulation range: Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg) Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg) Pulse volume: 0.1 cc ~ 2.4 cc HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance) Under patient condition: Weak pulse, tachycardia, obese, geriatric: ±(preset value 1%+1)bpm Moderate exercise: ±(preset value 1.5%+1)bpm Strenuous exercise: ±(preset value 3%+1)bpm Pressure measurement: Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Accuracy: 0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg 40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading Pressure leak test Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds. Over-pressure relief test Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure. Pressure source: Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc Airtightness Total airtightness: < 0.3 kPa/min (2.25 mmHg/min) under “OFF” state Airtightness of built-in cuff: 0.27 kPa/min (2 mmHg/min) BP simulation preset value configuration table BP simulation BP preset value BP HR Pulse volume Standard BP simulation #1 120/80(93) 80bpm 0.68cc #2 150/100(116) 0.65cc #3 200/150(166) 0.60cc #4 255/195(215) 0.55cc #5 60/30(40) 0.75cc #6 80/50(60) 0.71cc #7 100/65(76) 0.69cc BP simulation under patient condition Healthy heart 120/80(93) 75bpm 0.68cc Weak Pulse 110/80(90) 95bpm 0.50cc Mild Exercise 140/90(106) 120bpm 1.00cc Strenuous Exer 140/90(106) 162bpm 1.40cc Obese 120/80(93) 90bpm 0.50cc Geriatric 150/110(123) 95bpm 0.40cc Tachycardia 120/105(110) 130bpm 0.40cc Bradycardia 120/60(80) 45bpm 1.10cc BP simulation under arrhythmia condition Premature Atrial Contraction1 138/53(81) 80bpm 0.70cc Premature Atrial Contraction2 144/64(90) 83bpm Premature Ventricular Contraction 118/61(80) 83bpm Atrial Fibrillation and PVC 139/72(94) 91bpm BP simulation under respiratory interference condition spontaneous breathing1 138/65(89) 104bpm 0.60cc spontaneous breathing2 149/65(93) 105bpm spontaneous breathing3 112/47(68) 86bpm controlled breathing 132/44(73) 98bpm BP simulation of neonate #1 35/15(22) 120bpm 0.11cc #2 60/30(40) 0.10cc #3 80/50(60) #4 100/70(80) BP simulation of wrist cuff #1 120/80(93) 80bpm 0.50cc #2 160/100(120) #3 80/55(63) User-defined BP simulation[1] - - - - Note[1]:Support 9 user-defined BP simulation modes. The following parameters can be defined by users:2.3.1.The value of diastolic pressure should be lower than systolic pressure, pulse volume and HR can not be set to the highest values (e.g., pulse volume ≤ 2.00cc, HR: 250 bpm; pulse volume > 2.00cc, HR: 200bpm). Accessories One User Manual Two fuses One power cord Physical characteristic Display: 4.3" 65 K color LCD display Power supply: AC100 ~ 240 V 50/60 Hz, <60 VA Environment temperature: + 5 ℃ ~ + 40 ℃ Relative humidity: < 90 %, non-condensing Altitude: ≤ 3000 m Atmospheric pressure: 80 kPa ~ 106 kPa Dimension: 207 (L) × 220 (W) × 121 (H) mm Weight: about 2.1 kg