Water Spray Lance Assembly
OVERVIEW The HTS Water Spray Lance Assembly is a custom solution for the spent fuel bridge setup at Byron Generating Station. The assembly contains the following: Straight Wand Assembly (QTY 1): Chicago fitting (inlet) → 100ft hose → 25ft hose (optional) → isolation valve → quick disconnect → 5ft whip → 3/8 OD x 8ft long straight wand (no crimped outlet) U-Wand Assembly (QTY 1): Chicago fitting (inlet) → 100ft hose → 25ft hose (optional) → isolation valve → quick disconnect → 5ft whip → 3/8 OD x 8ft long tube, bent with end effector with 8" horizontal reach and 8" vertical end (no crimped outlet) Handrail-Mounted Hose Reel with Wand Holster (QTY 1): Adjustable clamp assembly designed to hold excess hoses and support the wand when not in use. KEY FEATURES FME-Compliant Design: Fully captured construction with no loose parts or hardware. Handrail Compatible: Designed to adapt to the handrail configuration at Byron and Braidwood. CONSTRUCTION Lightweight aluminum frame (bent