DigiRail Connect - Input/Output Modules with Ethernet and RS485 Connectivity

DigiRail Connect - Input/Output Modules with Ethernet and RS485 Connectivity

Was $346.98 SAVE 15%
$294.00

2 Analog Inputs (RAMIX Versions) - Thermocouples J, K, T, N, E, R, S and B, Pt100, Pt1000, NTC, 0-60 mV, 0-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA 2 Analog Outputs (RAMIX Versions) - 0-20 mA, 4-20 mA, 0-10 V 4 or 8 Digital Inputs (model dependent) Digital/Relay Outputs (model dependent) Ethernet, RS485 and USB Communication The DigiRail Connect is a versatile DIN rail I/O module with Ethernet, RS485 and USB interface which can be easily integrated to any automation system. With a flexible mix of industry-standard inputs and outputs, it performs  analog and digital signal handling with outstanding accuracy.  Bringing the Industry 4.0 to the DIN rail level, the connectivity of DigiRail Connect allows it to be used as a Modbus RTU slave in RS485 networks or as a Modbus TCP server over Ethernet. Specially designed to comply with international electromagnetic compatibility standards, it ensures robustness and reliability in the most demanding industrial applications.  Universal Analog InputsThe RAMIX-DO and RAMIX-RL have two universal  analog inputs which are software programmable for input type.  The two inputs are electrically insulated from the serial interface and the module power supply.  Features include: Analog inputs: programmable for thermocouples J, K, T, N, E, R, S , B,   Pt100, Pt1000, NTC, 0-60 mV, 0-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA Cold junction compensation for thermocouples and compensation for Pt100, PT1000 3-wire cables Open loop detection for thermocouple 10 Sample/sec sample rate  Analog input resolution: 16 bits Programmable filter Analog OutputsThe RAMIX-DO and RAMIX-RL also have two analog outputs. Features include: Configurable ranges of 0-20 mA, 4-20 mA, 0-10 V Settable power on state level Safe Value Watchdog - Allows you to set a value for the analog output in case of loss of communication. 12 bit resolution Digital InputsAll DigiRail Connect modules have digital inputs.  The DMIX models have 8 digital inputs and the RAMIX models have 4 digital inputs. Features include Programmable Measurement Function Logic Status Rising or Falling Edge  Counter (up to 250Hz for PNP or NPN, 10HZ for dry contact closure) Integrator (counts time in seconds when triggered by logic status) Programmable Signal Type Dry Contact with programmable debounce time NPN PNP Preset - allows an initial value to be set for the Rising Edge, Falling Edge, and Integrator ON/OFF counters.  Digtial and Relay OutputsThe RAMIX-DO has 3 digital outputs and the DMIX-DO has 8 digtial outputs.  The RAMIX-RL has 2 relays and the DMIX-RL has 4 relays. Digital Output/Relay Features include: Programmable Actuation Mode Logical Status Pulse - The output will turn on for a specific time interval (set in the Pulse Duration parameter) and then return to the OFF status Pulse Train - The  output will create a defined number of pulses (set in the Number of Pulses parameter), with a defined duration (set in the Pulse Duration parameter) and in a defined period (set in the Repetition Period parameter). Power On State Safe Status Watchdog - Allows the output state to be set in case of communication failure Ethernet, RS485 and USB CommunicationAll of the DigiRail Connect have Ethernet and RS485 communications.  The Ethernet connection uses Ethernet TCP protocol and the RS485 uses Modbus RTU protocol.  You can configure DigiRail Connect to operate in Gateway mode between a Modbus-TCP network and a Modbus RTU network.  The DigiRail Connect also has a USB port which is ideally intended for configuring and diagnosing the monitored process. Software NXperience - Configuration, Data Collection and Diagnostic Software (Free Download) NXperience is a free configuration, data collection and diagnostic software for NOVUS wireless transmitters and data loggers. This program allows you to explore all the features and details of the DigiRail Connect, and communicates through USB interface, TCP-IP and RS485 Interface. The NXperience allows configuration of the device and download of the data.  It  provides diagnostic tools which facilitates setup, operation, maintenance and trouble shooting of the device. . FieldChart Supervisory and Data Acquisition Software (Lite version available as a free download) FieldChart is a software used for monitor and register data acquired from NOVUS products. It generates real time trends and data lists that can be exported in usable formats like a spread sheet. There are two versions available: FieldChart-Lite and FieldChart-64C. The FieldChart-Lite can register 8 simultaneous channels and it is available for free. The FieldChart-64C can register up to 64 simultaneous channels. [to_order_table]  To Order the model below scroll to the top of the page then  click on ADD TO CART button  PART NUMBER DESCRIPTION RAMIX-RL DigiRail Connect with 2 Analog In, 2 Analog Out, 4 Digital In, 2 Relays RAMIX-DO DigiRail Connect with 2 Analog In, 2 Analog Out, 4 Digital In, 3 Digital Outputs DMIX-RL DigiRail Connect with 8 Digital In, 4 Relays DMIX-DO DigiRail Connect with 8 Digital In, 8 Digital Outputs Accessories CAB-USB-MICROB-3 Micro USB 2.0 Cable, Type A to Micro B, 3ft (used for USB communication with the DigiRail Connect) USB-i485 Isolated USB to RS485/RS422 Converter  [to_order_table]  Downloads DigiRail Connect User Manual DigiRail Connect Spec. Sheet NXperience Software FieldChart Lite Software   SPECIFICATIONSInput Channels  RAMIX Models: 4 Digital and 2 Analogs  DMIX Models: 8 Digital Output Channels  RAMIX Models: 3 Digital or 2 Relays and 2 Analogs  DMIX Models: 4 Relays or 8 DigitalAnalog InputsInput Ranges: Thermocouples J, K, T, N, E, R, S e B, Pt100, Pt1000, NTC, 0-60 mV, 0-5 Vdc, 0-10 Vdc, 0-20 mA, 4-20 mA Accuracy  Thermocouples: 0.2 % of maximum range  Pt100, Pt1000, NTC, mA, V, mV: 0.15 % of the maximum range  Thermocouple Cold Junction Error: ± 1 °C / ± 1.8 °F (J,K,T), ± 3 °C / ± 5.4 °F (N, E, R, S, B) Analog Input Impedance  0-60 mV, Pt100, Pt1000, NTC and thermocouples : >10 MΩ  0-5 V, 0-10 V: >1 MΩ  4-20 mA: 15 Ω + (1 V @ 20 mA) Pt100 Maximum Compensated Cable Resistance: 20ΩPt100 Excitation current: 0.60 mAResolution: 16 bits (65536 levels)Digital InputLogical Levels: Logical Level "0": < 0.5 V, Logical Level "1": > 3 VMaximum Voltage: 30 VInput Impedance: 270 kΩInput Current @ 30 Vdc: 0.15 mA(typical) Maximum Frequency (square wave)  Dry Contact: 10 Hz  PNP: 250 Hz  NPN: 250 Hz Minimum Pulse Duration  Dry Contact: 50 ms  PNP: 4 ms  NPN: 4 msTransistor Digital Output  Output Type: Sourcing  Maximum Load Current: 500 mA  Short-circuit Current: 70 mA  Maximum Switching Voltage: 30 Vdc  Minimum Switching Voltage: 6 VdcRelay Digital Output  Type: SPST-NO and SPDT  Maximum Load Current: 3 A (SPST) / 6 A (SPDT)  Switching Voltage: 250 Vac  Suitable for resistive loadsAnalog Output  Signal Types: 0-20 mA, 4-20 mA, 0-10 V  Maximum Load: 0-20 / 4-20 mA: = 500 Ohms, 0-10 V: = 2000 Ohms  Resolution: 12 bits  Accuracy: 0.5 %Communication Interfaces  USB  Ethernet: 10/100 Mb/s, IEEE standard 802.3u  RS485Power Supply  Voltage: 10 Vdc to 36 Vdc  Maximum Consumption: 5 W  Typical Consumption: 20 mAOperating Temperature: -20 to 60 °COperating Humidity: 5 to 95 % RH, non-condensingHousing: ABS+PCProtection Rating: IP2ODimensions: 100 x 30 x 110 mm

Show More Show Less

Price History

$346.98 $294 (-$52.98)