FLUKE-726/FPC Multifunction Calibrator Precision Multifunction, HART, 0.001 mA – 24 mA, NIST

FLUKE-726/FPC Multifunction Calibrator Precision Multifunction, HART, 0.001 mA – 24 mA, NIST

$7,850.45

Multifunction Calibrator, Voltage Measurement Range -10 to 75 mV, Loop Supply Voltage 24 V, Intrinsically Safe No, Pressure Modules 29, Measurement Functions Hertz, mV, Ohms, V, Source Current 24 mA DC, Current Measurement Range 0 to 24 mA DC, Basic DC Accuracy +/- 0.01 Percent + 2mV, Thermocouple Temperature Range -250 Degrees to 2500 Degrees C, Powered By (4) AA Batteries, Includes Alligator Clips, Stackable Test Leads, Test Leads, Frequency Source Range 10.0 to 15.0 kHz Includes Alligator Clips, Stackable Test Leads, Test Leads Standards ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN 61010-1:1993 Calibration Certificate NIST Thermocouple Type B, BP, E, J, K, L, N, R, S, T, U, XK RTD Type Cu10, Ni120, Pt100 (385), Pt100 (391-JIS), Pt100 (392), Pt1000 (385), Pt200 (385), Pt500 (385) Safety Rating ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN61010-1:1993 Current Measurement Range 0 to 24 mA DC Source Voltage -10 to 75 mV Powered By (4) AA Batteries Pressure Modules 29 Measurement Functions Hertz, mV, Ohms, V Frequency Source Range 10.0 to 15.0 kHz Intrinsically Safe No Source Current 24 mA DC Voltage Measurement Range -10 to 75 mV Loop Supply Voltage 24 V Basic DC Accuracy +/- 0.01% + 2mV Max. Loop Current 22 mA Resistance Measurements 0 to 4,000 ohm Resistance Source 1,500 to 4,000 ohm Thermocouple Temperature Range -250 Degrees to 2500 Degrees C Source/Simulate Hertz, mA, mV, Ohms, V Frequency Measurement Range 10.0 to 15.0 kHz Number of Batteries Required 4 Resistance Measurement - Minimum 0 ohm Parameters Measured DC Current, DC Voltage, Frequency, Pressure, Resistance, RTD, TC Resistance Measurement - Maximum 4,000 ohm Source Current - Maximum 24 mA Frequency Measurement - Minimum 1 kHz Source Frequency - Minimum 10 kHz Source Voltage - Maximum 75 mV Current Measurement - Maximum 24 mA Frequency Measurement - Maximum 15 kHz Battery Chemistry Alkaline Voltage Measurement - Maximum 75 mV Loop Current - Maximum 22 mA Current Measurement - Minimum 0 mA Thermocouple Temperature - Minimum 482 Degrees F Source Resistance - Minimum 1,500 ohm Parameters Sourced AC Voltage, DC Voltage, Frequency, Resistance Source Resistance - Maximum 4,000 ohm Intrinsic Safety Not Specified Intrinsically Safe Thermocouple Temperature - Maximum 4,532 Degrees F Source Voltage - Minimum -10 mV Includes Batteries Batteries Included Calibration Certificate Type NIST Source Frequency - Maximum 15 kHz Digital Display Screen Type LCD with Backlight Source Current - Minimum 0.001 mA Voltage Measurement - Minimum -10 mV Communication Protocol HART

Show More Show Less