Jeio Tech Programmable OF4 Forced Convection Ovens
Overview Unattended operation is absolutely available with the intelligent programmable controller. Easy setting program temperature for everyone. Real-time monitoring to check status of device. Convenient checking for the test progress and data. Structural and functional features for improved user convenience. Reliable temperature control performance based on stable control mechanisms Features: User interface that provides a quick view of temperature changes(heating, stable, and cooling) and fan speed also. Set various test condition using 10 programs and 10 steps, which can be repeated up to 99 times. Start temperature, temperature and time for each step, and Opti-flowTM all adjustable as desired. Opti-flow™, a function to flexibly adjust the fan speed according to the specimen type and test conditions. Stacking Kit (optional) ensuring the safe fitting of one unit to another, thus doubling the amount of work done in a given area for improved space efficiency. Hands-free™ door system to allow users to easily open the door while carrying samples with both hands. BMS communication port that helps monitor the device temperature on the building management system, enabling quick response in case of abnormality. (option) Monitor and control via mobile app anytime, anywhere with LC Connected. (mobile monitoring system) (option) RS-232/USB port and compatible software provided to enable easy device control and data management using PC. Test data is automatically saved and easily downloaded via USB; easy to edit and use. (in CSV format) 36 latest events, such as errors and door opened or closed, automatically recorded, helping user obtain feedback on experimental results. Wide temperature range of up to 250℃. Three-point temperature calibration that ensures high temperature accuracy over a wide temperature range. Ramping rates (℃/min) flexibly adjustable for each test performed. Excellent temperature distribution through the formation of optimal airflow for uniform heat transfer. (±1.9℃ or below at 100℃) Key Attributes Max Temperature 250°C Max Capacity 0.92, 2.15, 3.96 or 5.19 cu ft Air Movement Forced Electrical 120V Warranty 1 (2 years after submission of warranty registration card) Manufacturer Specifications Model Solid door (without window) OF4-03P OF4-05P OF4-10P OF4-15P Window door OF4-03PW OF4-05PW OF4-10PW OF4-15PW Chamber volume (L/cu ft) 26/0.92 61/2.15 112/3.96 147/5.19 Temperature 1) Range (℃/℉) Amb. + 10~250 / Amb. + 18 ~ 482 Fluctuation at 100℃ (±℃/±℉) 0.3/0.54 0.3/0.54 0.3/0.54 0.3/0.54 Variation at 100℃ (±℃/±℉) 1.4/2.52 1.9/3.42 1.7/3.06 1.5/2.70 Heating time to 100℃ (min) 8 10 14 15 Recovery time at 100℃ (min) 4 4 4 4 Control Panel 5inch TFT Color LCD Communication interface USB, RS-232, BMS Function Program setting 10 program, 10 step, start temp. Scehdular Set day, time, and program No Recently event record 36ea Fan speed adjustable Three-step wind speed settings Recommended temperature Three frequently used temperature settings suggested Graph Available checking the stored and real-time data as graphs Data storage Save the test data in CSV format Temp. ramping rate (℃/min. / ℉/min.) 0~13/0~23.4 0~9/0~16.2 0~6/0~10.8 0~5/0~9 Dimensions Interior (W x D x H, mm/inch) 300 x 210 x 400 /11.80 x 8.27 x 15.75 380 x 330 x 480 /14.97 x 13.0 0x 18.90 485 x 350 x 655 /19.09 x 13.78 x 25.79 550 x 376 x 710 /21.65 x 14.80 x 27.95 Exterior (W x D x H, mm/inch) 478 x 527 x 604 /18.82 X 20.75 X 23.78 558 x 648 x 684 /21.97 X 25.51 X 26.93 663 x 677 x 859 /26.1 X 26.65 X 33.82 728 x 704 x 914 /28.66 X 27.72 X 35.98 Net weight (kg/lbs) 33/72.8 53/116.8 63/138.9 73/160.9 Shelves Quantity of shelves (Standard/max.) 2/4 2/5 2/8 2/9 Max. Load per shelf (kg/lbs) 30/66.1 Number of Air change per hour at 100 ℃ 2) 123 22 18 11 Electrical requirements (230V, 50/60Hz, A) 6.4 Cat. No. Solid door (without window) AAH12915K AAH12925K AAH12935K AAH12945K Window door AAH12955K AAH12965K AAH12975K AAH12985K Electrical requirements (120V, 60Hz, A) 12.3 Cat. No. Solid door (without window) AAH12916U AAH12926U AAH12936U AAH12946U Window door AAH12956U AAH12966U AAH12976U AAH12986U 1) This data was measured when the fan speed was set to Step 5. If the fan speed is set to Step 1 or Step 3, the fluctuation and variation values will increase. (According to DIN 12880, before 2013)2) This data was measured when the fan speed was set to Step 5. If the fan speed is set to Step 1 or Step 3, the number of air changes may decrease. (According to ASTM D 5374, reapproved 1999) Model OF-03P OF4-05P OF4-10P OF4-15P A: Maximum depth with door opened 868 / 34.2 1060 / 41.7 1185 / 46.7 1271 / 50.0 B: Maximum width with door opened 695 / 27.4 809 / 31.9 958 / 37.7 1050 / 41.3 C: Interior width 300 / 11.8 380 / 15.0 485 / 19.1 550 /21.7 D: Interior height 400 / 15.7 480 / 18.9 655 / 25.8 710 / 28.0 E: Interior depth 210 / 8.3 330 / 13.0 350 / 13.8 376 / 14.8 F: Shelve width 266 / 10.5 346 / 13.6 451 / 17.8 516 / 20.3 G: Shelve depth 195 / 7.7 315 / 12.4 335 / 13.2 361 / 14.2 H: Gap between shelf racks 30 / 1.2 30 / 1.2 30 / 1.2 30 / 1.2 I: Gap between uppermost shelve and interior ceiling 80 / 3.1 90 / 3.5 88 / 3.5 85 / 3.3 J: Space for sensor installation 3.8 / 0.15 3.8 / 0.15 3.8 / 0.15 3.8 / 0.15