
Fluke 115/APAC True Rms Digital Multimeter
FLUKE-115/APAC True-RMS Digital Multimeter (item no. 5294289) General purpose digital multimeter for electrical and electronic testing Ideal for quick verifications and field service Presents a large white LED backlight for working in poorly lit areas Measures AC and DC voltage to 600V Measures AC and DC current to 10A (20 A overload for 30-seconds max) The FLUKE-115/APAC is the compact, general purpose troubleshooting tool for field service technicians For general purpose electrical and electronic test requirements, the Fluke 115 True RMS digital multimeter provides the perfect answer. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications. Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments. Other useful features: Measures resistance, continuity, frequency, and capacitance Provides Min/Max/Average with elapsed time to record signal fluctuations Comes with a holster with probe holders for easy storage Features a compact ergonomic design for one-handed operation Fits into optional ToolPak™ magnetic hanger for hands-free operation CAT III 600 V safety rated Specifications: FLUKE-115/APAC True-RMS Digital Multimeter Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to + 50°C Storage temperature -40°C to + 60°C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/resolution 6.000 V / 0.001 V60.00 V / 0.01 V600.00 V / 0.1 V Accuracy ± ([% of reading] + [counts]): 0.5% + 2 AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz) AC volts1 True RMS Range/resolution 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)2.0% + 3 (500 Hz to 1 kHz) Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of500 μs or longer. Ohms Range/resolution 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ Accuracy 0.9% + 1 Range/resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% + 2 Diode test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% + 2 Capacitance Range/resolution 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF / 1 μF100 μF to 1000 μF Accuracy 1.9% + 2 Range/resolution > 1000 μF Accuracy 5% + 20% Lo-Z capacitance Range 1 nF to 500 μF Accuracy 10% + 2 typical AC amps True RMS(45 Hz to 500Hz) Range/resolution 6.000 A / 0.001 A10.00 A / 0.01 A Accuracy 1.5% + 320 A overload for 30-seconds max DC amps Range/resolution 6.000 A / 0.001 A10.00 A / 0.01 A Accuracy 1.0% + 320 A overload for 30-seconds max Hz (V or A input)2 Range/resolution 99.99 Hz / 0.01 Hz999.9 Hz / 0.01 Hz9.999 kHz / 0.001 kHz50 kHz / 0.01 kHz Accuracy 0.1% + 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years Includes: Holster Installed 9V battery 4 mm silicone test lead set User manual Manuals 114, 115, 117 | Users manual 114, 115, 117 | Users manual supplement 114, 115, 116, and 117 | Calibration information 114, 115, 116, and 117 | Calibration information supplement 117, 116,115,114,113 and 110 Plus | Statement of memory volatility Data Sheets Add wireless to your Fluke digital multimeter Extended Specs For 114, 115, 116, 117 Fluke 115 Multimeter Data Sheet