
Fluke 1586A Super-DAQ 2 DAQ-STAQ Modules 240V
1586A Super-DAQ 2 DAQ-STAQ Modules 240V (Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 ) (item no. 4410023) The 1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for bench top sensor calibration in the lab. It collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyse interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analysing the data on a PC. When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best bench top reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples. Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration dry well or bath and Automated Sensor Test routines are run. Some temperature data acquisition applications require compliance to government and standards agency requirements. TQSoft and TQAero thermal validation software help engineers, technicians and lab managers to meet the key guidelines for temperature data collection. These software solutions provide a complete qualification, reporting, documentation, and audit trail management system. FEATURES The 1586A Super-DAQ reads PRTs, thermocouples, and thermistors with best-in-class accuracy: PRTs ± 0.005 °C (using external DAQ-STAQ Multiplexer) Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC) Thermistors: ± 0.002 °C Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM) Chart up to four channels simultaneously Administrator and user profiles for protecting settings and ensuring test traceability Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines Input channels: Up to 40 isolated universal inputs Selectable scan speed: Up to 10 channels per second Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance Current reversal minimises thermoelectric effects, improving PRT/RTD measurement accuracy Two rear panel slots can be configured for the internal High-Capacity Module or the external DAQ-STAQ Multiplexer - or one of each Navigation keys for fast selection of information Standby key turns the display and keypad off which eliminates warm-up time Function soft keys support fast setup and operation Measure/DMM function for quick measurements and recording with minimal setup Line voltage and fuse selector Power switch and line cord connector USB and Ethernet ports used for remote operation Digital external alarm trigger outputs Mx + B scaling and channel offset zero function Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection 6 1/2 digit display resolution for dc voltage, dc current, and resistance APPLICATIONS Thermal mapping Temperature validation Process sensor calibration Automotive Pharmaceutical Biotechnology Food processing Aerospace SPECIFICATIONS PRT/RTD (100 Ω Nominal) Temperature Range -200 to 1200°C (depending on the sensor) Temperature Resolution 0.001°C Temperature Accuracy 0.005°C at -200°C0.005°C at 0°C0.012°C at 300°C Resistance Accuracy 0.002% or 0.008 Ω Excitation Current 1 mA with current reversal Thermistor (10 KΩ Nominal) Temperature Range -200 to 400°C (depending on the sensor) Temperature Resolution 0.0001°C Temperature Accuracy 0.002°C at 0°C0.009°C at 50°C0.024°C at 100°C Resistance Accuracy 0.004% + 0.5 Ω Excitation Current 10 μA Thermocouple Type K Temperature Range -270 to 1372°C Temperature Resolution 0.01°C/td> Temperature Accuracy (int CJC) 0.29°C at 0°C0.32°C at 1000°C Temperature Accuracy (ext CJC) 0.15°C at 0°C0.20°C at 1000°C Voltage Accuracy 0.004% + 4 μV ch. 10.004% + 6 μV ch. x01-x20 Thermocouple Type T Temperature Range -270 to 400°C Temperature Resolution 0.01°C Temperature Accuracy (int CJC) 0.30°C at 0°C0.23°C at 200°C Temperature Accuracy (ext CJC) 0.15°C at 0°C0.12°C at 200°C Voltage Accuracy 0.004% + 4 μV ch. 10.004% + 6 μV ch. x01-x20 Thermocouple Type S Temperature Range -50 to 1768°C Temperature Resolution 0.01°C Temperature Accuracy (int CJC) 0.68°C at 300°C0.55°C at 1200°C Temperature Accuracy (ext CJC) 0.67°C at 300°C0.54°C at 1200°C Voltage Accuracy 0.004% + 4 μV ch. 10.004% + 6 μV ch. x01-x20 DC Voltage (Medium or Slow Sample Rate) Range ±100 mV±50 V Accuracy Channel 1 0.0037% + 0.0035%0.0038% + 0.0012% Ch. X01 - x202 Add 2 μV Fast Sample Rate Add 0.0008% of range Resolution 0.1 μV1 mV Input Impedance 10 GΩ [1]10 MΩ ±1% DC Current (Medium or Slow Sample Rate) Range ±100 μA±10 mA±100 mA Accuracy 0.015% + 0.0035% Fast Sample Rate Add 0.0008% of range Resolution 0.1 nA10 nA100 nA Burden Voltage <1 mV Resistance (Medium or Slow Sample Rate, 4-Wire Resistance) Range 100 Ω10 kΩ10 MΩ Accuracy 0.004% + 0.0035%0.004% + 0.001%0.015% + 0.001% Fast Sample Rate Add 0.001% of rangeAdd 0.01% of range Resolution 0.1 mΩ10 mΩ1 kΩ Source Current 1 mA100 μA0.1 μA General Specifications Channel Capacity Total analog channels: 45Voltage/resistance channels: 41Current channels: 5Digital I/O: 1 (8-bit TTL)Totalizer: 1Alarm outputs: 6Trigger input: 1 Sample Rate Fast: 10 channels per second (0.1 seconds per channel)Medium: 1 channel per second (1 second per channel)Slow: 4 seconds per channel Display Resolution 6 1/2 digits Input Module Options 2 rear panel slots ('x' designates slot 1 or slot 2 below) Internal High-Capacity Module configuration 20 channels per module (x01 - x20)2 dedicated current channels (x21 - x22)(3- and 4-wire connections require 2 channels) Math Channels 20 channelsOperations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum Triggers Interval, external (trigger input), alarm, remote (bus), manual, automated test Memory Scan data RAM: 75,000 readings with timestampInternal memory: 20 MB Standard Interfaces USB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths Mains Voltage 100 V setting: 90 to 100 V120 V setting: 108 to 132 V220 V setting: 198 to 242 V240 V setting: 216 to 264 V Mains Frequency 47 to 440 Hz Input Protection 50 V all functions, terminals and ranges Dimensions 5.9 x 9.6 x 15.2" (150 x 245 x 385 mm) Weight 13.2 lbs (6 kg) Conformity CE, CSA, IEC 61010 3rd edition