
Fluke 726/APAC/EDC Precision Multifunction Calibrator
Fluke 726/APAC/EDC Precision (Prev. Fluke-726) Multifunction Process Calibrator designed specifically for the process industry (item no. 5131133) The FLUKE726/APAC/EDC is a precise and powerful, yet easy-to-use field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves and test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis. Features Precision multifunction process calibrator designed specifically for the process industry Delivers precise measurement and calibration source performance with accuracies of 0.01%. Stores up to eight calibration results in memory for later analysis Offers HART mode that inserts a 250 ohm resistor in mA measure and source for compatibility with HART instrumentation Other useful features: A backlit display provides better visibility in poor light • Stores frequently-used test setups for later use Program custom RTD probe calibration constants of certified RTD probes for enhanced temperature measurement Voltage input protection design for improved reliability Three-year warranty If you need an intrinsically-safe rated calibrator, consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator. If you want documenting and HART communication built into your calibrator, consider the Fluke 754 Documenting Process Calibrator with HART. Features frequency totalizer and frequency pulse train source mode for enhanced flowmeter testing Measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters Sources/simulates volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters Measures or sources pressure using any of 50 Fluke 750P series Pressure Modules Sources mA with simultaneous pressure measurement to conduct valve and I/P tests Provides two separate channels to measure, source and view process signals simultaneously Provides an integrated pressure switch test to allow you to capture the set, reset, and deadband of a switch Provides transmitter error % calculation to interpret calibration results without a calculator Performs fast linearity tests with auto-step and auto-ramp features Powers transmitters during test using 24 V loop supply and simultaneous mA measurement If you need an intrinsically-safe rated calibrator, consider the Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator. If you want documenting and HART communication built into your calibrator, consider the Fluke 754 Documenting Process Calibrator with HART. Models: FLUKE726/APAC/EDC Precision Multifunction Calibrators FLUKE726/APAC/EDC FLUKE726/APAC/EDC Precision Multifunction Process Calibrator Buy now Includes: One set of AC72 alligator clips One set of stackable test leads One set of TL75 testleads User manuals NIST- traceable calibration report and data Specifications: FLUKE726/APAC/EDC Precision Multifunction Calibrators Measurement Accuracy Voltage DC 30.000 V 0.01% + 2 mV (upper display) 20.000 V 0.01% + 2 mV (lower display) 90.00 mV 0.01% + 10 μV -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector) Current DC 24.000 mA 0.01%+ 2 mA Resistance 0.0 to 4000.0 Ω ± 0.015% Frequency 2.0 to 1000.0 CPM 0.05% + 0.1 cpm 1.0 to 1000.0 Hz 0.05% + 0.1 Hz 1.00 to 15.00 kHz 0.05% + 0.01 kHz Sensitivity 1 V peak-to-peak-minimum Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. Source Accuracy Voltage DC 100.00 mV 0.01% + 10 μV 20.000 V 0.01% + 2 mV -10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector) Current DC 24.000 mA (Source) 0.01% + 2 μA 24.000 mA (Simulate) 0.01% + 2 μA Resistance Range, accuracy (percent of reading + floor) and excitation current 5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA 5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA 400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA 1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA Frequency 2.0 to 1000.0 CPM 0.05% 1.0 to 1000.0 Hz 0.05% 1.0 to 10.0 kHz 0.25% 10.0 to 15.0 kHz 0.5% Waveform 5 V p-p squarewave, -0.1 V offset RTDs and Thermocouples Measure and source accuracy Cu10 1.8°C NI-120 0.15°C PT-100 (385) 0.45°C PT-100 (392) 0.35°C PT-100 (391-JIS) 0.35°C PT-200 (385) 0.95°C PT-500 (385) 0.55°C PT-1000 (385) 0.35°C RTD Resolution 0.01°C (0.01°F) Cu10.01 C 0.1°C (0.1°F) J 0.4°C K 0.5°C T 0.4°C E 0.4°C R 1.4°C S 1.4°C B 1.4°C L 0.45°C U 0.45°C N 0.6°C XK 0.4°C BP 1.1°C TC Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F Specifications Ramp functions Source functions Voltage, current, resistance, frequency, temperature Ramps Slow ramp, Fast ramp, 25% step-ramp Loop power function Voltage 24 V Accuracy 10% Maximum current 22 mA, short circuit protected Step functions Source functions Voltage, current, resistance, frequency, temperature Steps 25% of range, 100% of range Environmental Specifications Operating temperature -10°C to +55°C Storage temperature -20°C to +71°C Operating altitude 3000 m Safety Specifications Agency approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 Mechanical and General Specifications Size 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in) Weight 650 g (23 oz) Batteries 4 AA alkaline batteries Battery replacement Separate battery compartment, accessible without breaking calibration seal Side port connections Pressure module connector, also used for remote real-time programming Resources: FLUKE726/APAC/EDC Precision Multifunction Calibrators Manuals 726 | Users manual 726 | Users manual supplement 718,719,724,725, 726 | Safety sheet 724/725/726 | Calibration manual Data Sheets 726 Precision Multifunction Process Calibrator