
Fluke 729 30G FC 30 PSI, 2 Bar Automatic Pressure Calibrator, W/ Fluke Connect
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 ) 729 30G FC 30 PSI, 2 Bar Automatic Pressure Calibrator, W/ Fluke Connect (item no. 4856907) Product overview: Fluke 729 Automatic Pressure Calibrator Portable automatic pressure calibrator simplifies pressure calibration The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package. The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilizes the pressure at the requested value. The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest. Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values. Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data. With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them. Features Automatic pressure generation and regulation to 300 psi Easily document the process using onboard test templates Automatic internal fine-pressure adjustment Measure, source and simulate 4 to 20 mA signals 24V loop power for powering transmitters for tests Bright dual/triple-channel color graphical display HART communication for testing HART smart transmitters Built-in leak testing for verifying test setups for leakage Rugged portable design with standard 3-year warranty Fluke Connect® App compatibility Measure temperature with optional 720RTD probe Measure Vdc for testing 1 V dc to 5 V dc output transmitters Compatible with 700 Series and 750 Series pressure modules Upload documented test results to DPCTrack2™ Calibration Management Software Innovative semi-rigid carrying case designed for field work Specifications: Fluke 729 Automatic Pressure Calibrator Pressure specification* One-year specification 0.02% of full scale Control specification 0.005% full scale minimum *See manual for detailed specifications Model 729 30G Psi range, resolution -12.0000 to 30.0000 psi Bar range, resolution -0.82737 to 2.06842 bar kPa range, resolution -82.737 to 206.843 kPa Comment No wireless communication 729 150G Psi range, resolution -12.000 to 150.000 psi Bar range, resolution -0.8273 to 10.3421 bar kPa range, resolution -82.73 to 1034.21 kPa Comment No wireless communication 729 300G Psi range, resolution -12.000 to 300.000 psi Bar range, resolution -0.8273 to 20.6843 bar kPa range, resolution -82.73 to 2068.43 kPa Comment No wireless communication 729 30G FC Psi range, resolution -12.0000 to 30.0000 psi Bar range, resolution -0.82737 to 2.06842 bar kPa range, resolution -82.737 to 206.843 kPa Comment Wireless communication for Fluke Connect 729 150G FC Psi range, resolution -12.000 to 150.000 psi Bar range, resolution -0.8273 to 10.3421 bar kPa range, resolution -82.73 to 1034.21 kPa Comment Wireless communication for Fluke Connect 729 300G FC Psi range, resolution -12.000 to 300.000 psi Bar range, resolution -0.8273 to 20.6843 bar kPa range, resolution -82.73 to 2068.43 kPa Comment Wireless communication for Fluke Connect 729CN 200K Psi range, resolution -12.0000 to 30.0000 psi Bar range, resolution -0.82737 to 2.06842 bar kPa range, resolution -82.737 to 206.843 kPa Comment For China, no wireless communication 729CN 1M Psi range, resolution -12.000 to 150.000 psi Bar range, resolution -0.8273 to 10.3421 bar kPa range, resolution -82.73 to 1034.21 kPa Comment For China, no wireless communication 729CN 2M Psi range, resolution -12.000 to 300.000 psi Bar range, resolution -0.8273 to 20.6843 bar kPa range, resolution -82.73 to 2068.43 kPa Comment For China, no wireless communication 729CN 200K FC Psi range, resolution -12.0000 to 30.0000 psi Bar range, resolution -0.82737 to 2.06842 bar kPa range, resolution -82.737 to 206.843 kPa Comment For China, wireless communication for Fluke Connect 729CN 1M FC Psi range, resolution -12.000 to 150.000 psi Bar range, resolution -0.8273 to 10.3421 bar kPa range, resolution -82.73 to 1034.21 kPa Comment For China, wireless communication for Fluke Connect 729CN 2M FC Psi range, resolution -12.000 to 300.000 psi Bar range, resolution -0.8273 to 20.6843 bar kPa range, resolution -82.73 to 2068.43 kPa Comment For China, wireless communication for Fluke Connect 729JP 200K kPa range, resolution -82.737 to 206.843 kPa Comment For Japan, no wireless communication 729JP 1M kPa range, resolution -82.73 to 1034.21 kPa Comment For Japan, 1 MPa range, no wireless communication 729JP 2M kPa range, resolution -82.73 to 2068.43 kPa Comment For Japan, 2 MPa range, no wireless communication 729JP 200K FC kPa range, resolution -82.737 to 206.843 kPa Comment For Japan, wireless communication for Fluke Connect 729JP 1M FC kPa range, resolution -82.73 to 1034.21 kPa Comment For Japan, wireless communication for Fluke Connect 729JP 2M FC kPa range, resolution -82.73 to 2068.43 kPa Comment For Japan, wireless communication for Fluke Connect Electrical specification All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range. Ranges mA measure, source and simulate 0 mA to 24 mA Volts dc measure 0 V dc to 30 V dc Resolution mA dc source, simulate and measure 1 μA Voltage dc measurement 1 mV Accuracy 0.01% ±2 LSD all ranges (at 23 °C ±5 °C) Stability 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C mA simulate external voltage requirement 12 V dc to 30 V dc Loop compliance voltage 24 V dc @ 20 mA mA simulate external voltage requirement 12 V dc to 30 V dc Temperature measurement only/100 Ω Pt(385) RTD -50 °C to 150 °C (-58 °F to 302 °F) Temperature resolution 0.01 °C (0.01 °F) Temperature accuracy ±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory) Drive capability 1200 Ω without HART resistor, 950 Ω with internal HART resistor Mechanical specification Size (HxWxL) 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in) Weight 6.5 lbs., 2.95 kg Ingress protection IP54 Environmental specification Operating temperature -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control Operating temperature with battery -10 °C to 40 °C Battery will only charge to 40 °C Storage temperature -40 °C to 60 °C Operating altitude 3000 m Storage altitude 13000 m Wireless (729 FC only) Radio frequency certification FCC ID: T68-FBLE IC:6627A-FBLE Wireless radio frequency range 2412 MHz to 2462 MHz Manuals 729/729 FC | Users manual 729/729 FC | Users manual supplement 729/729 FC | Quick reference guide 729/729 FC | Safety sheet 729/729 FC | Calibration manual 729/729 FC | Calibration manual supplement 729/729 FC | Statement of memory volatility Radio Frequency Data Class B | Instruction sheet Data Sheets Fluke 729 Automatic Pressure Calibrator | Data Sheet