
Fluke A3001 FC Wireless iFlex® AC Current Clamp Kit With I3000
(item no. 4465665) Product Overview Fluke FLK-A3001 FC KIT Connect the a3001 FC Wireless AC Current Module and flexible current probe to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Features The Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit provides measurement of many common electrical parameters The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting: AC and DC voltage measurements to 1000V AC and DC current with 0.01 mA resolution Continuity, resistance, diode test, capacitance and frequency measurements MIN/MAX recording CAT III 1000 V, Cat IV 600 V; IP54 The Fluke a3001 FC Wireless iFlex® AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier: Measure up to 2500 A AC Use as a standalone meter or as part of the system Logging function for recording and saving up to 65,000 readings Inrush function Specifications: Fluke a3001 FC Wireless iFlex® AC Current Clamp Kit Fluke 3000 FC Series Wireless Multimeter * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]). AC Voltage Range¹ / resolution 600.0 mV / 0.1 mV6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V1000 V / 1 V Accuracy2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 kHz 2.0% + 3 1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. DC Voltage, Continuity, Resistance, Diode Test and Capacitance mV Range / resolution 600.0 mV / 0.1 mV Accuracy 0.09% + 2 V Range / resolution 6.000 V / 0.001 V60.00 V / 0.01 V600.0 V / 0.1 V 1000 V / 1 V Accuracy 0.09% + 20.15% + 2 ))) Range / resolution 600 Ω / 1 Ω Accuracy Meter beeps at Ω Range / resolution 600.0 Ω / 0.1 Ω6.000 kΩ / 0.001 kΩ60.00 kΩ / 0.01 kΩ60.00 kΩ / 0.1 kΩ600.0 kΩ / 0.001 MΩ50.00 MΩ / 0.01 MΩ Accuracy 0.5% + 20.5% + 11.5% + 3 Diode test Range / resolution 2.000 V / 0.001 V Accuracy 1% + 2 µF Range / resolution 1000 nF / 1 nF10.00 μF / 0.01 μF100.0 μF / 0.1 μF9999 μF1 / 1 μF Accuracy 1.2% + 210% typical 1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. AC and DC Current mA AC (45 Hz to 1 kHz) Range1 / resolution 60.00 mA / 0.01 mA400.0 mA3/ 0.1 mA Accuracy 1.5% + 3 mA DC2 Range1 / resolution 60.00 mA / 0.01 mA400.0 mA3/ 0.1 mA Accuracy 0.5% + 3 1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. Frequency Range / resolution 99.99 Hz / 0.01 Hz999.9 Hz / 0.1 Hz9.999 kHz / 0.001 kHz99.99 kHz / 0.01 kHz Accuracy1 0.1% + 1 1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. Input Characteristics Overload protection 1100 Vrms Input impedance (nominal) > 10 MΩ Common mode rejection ratio (1 kΩ unbalance) > 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Overload protection 1100 Vrms Input impedance (nominal) > 10 MΩ Common mode rejection ratio (1 kΩ unbalance) > 60 dB, DC to 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Overload protection 1100 Vrms Input impedance (nominal) > 10 MΩ Common mode rejection ratio (1 kΩ unbalance) > 120 dB at DC, 50 Hz or 60 Hz Normal mode rejection > 60 dB at 50 Hz or 60 Hz Open Circuit Test Voltage Overload protection 1100 Vrms Input impedance (nominal) Full scale voltage to 6 MΩFull scale voltage 50 MΩ Typical short circuit current Overload protection 1100 Vrms Input impedance (nominal) Full scale voltage to 6 MΩFull scale voltage 50 MΩ 2.000 VDC Typical short circuit current mA Function Overload protection Fused, 44/100 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum MIN/MAX Recording Accuracy DC functions ±12 counts for changes > 350 mS in duration. AC functions ±40 counts for changes > 900 mS in duration. General Specifications Maximum voltage between any terminal and earth ground 1000 VDC or AC rms Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate 4/sec Volts, amps, ohms 6000 counts Frequency 10,000 counts Capacitance 1,000 counts Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6 Battery life 250 hours minimum RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m Temperature Operating -10°C to 50°C Storage -40°C to 60°C Temperature coefficient 0.1 x (specified accuracy) / °C ( 28°C) Relative humidity 0% to 90% (0°C to 35°C)0% to 75% (35°C to 40°C)0% to 45% (40°C to 50°C) Altitude Operating 2,000 m Storage 12,000 m Electromagnetic compatibilityEMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489V1.8.1:2008FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd editionCAN/CSA-C22.2 No 61010-1-12: 3rd editionUL 61010-1: 3rd edition IEC/EN 61010-1:2010 Certifications CSA, FCC, CE Ingress Protection (IP) rating IP54 Pollution Degree 2 Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight 340 g (12 oz) Warranty Three years Not compatible with Fluke CNX test tools Fluke a3001 FC Wireless iFlex® AC Current Module Specifications Range 0.5 A to 2500 A AC Resolution 0.1 A Accuracy 3% ±5 digits (5 Hz to 500 Hz) Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A2.5 at 1400 A1.42 at 2500 AAdd 2% for C.F. > 2 LCD w/ backlight 3½ digits Log rate/interval 1 sec minimum/adjustable by PC or front panel Battery type 2 AA, NEDA 15 A, IEC LR6 Battery life 400 hours Memory Record up to 65,000 readings RF communications 2.4 GHZ ISM Band RF communication range Open air, unobstructed Up to 20 m Obstructed, sheetrock wall Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Temperature coefficient Add 0.1 x (specified accuracy) / °C ( 28°C) Operating humidity 90% at 35°C75% at 40°C 45% at 50°C Altitude Operating 2,000 m Storage 12,000 m EMC EN 61326-1:2006 Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition Safety rating CAT IV 600 V, CAT III 1000 V Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE Ingress Protection (IP) rating IP42 Pollution Degree 2 Jaw opening 25.4 cm (10 in) coil Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) Weight .22 kg (8 oz) Warranty Three years Not compatible with Fluke CNX test tools Includes: Fluke 3000 FC Series Wireless Multimeter Fluke a3001 FC Wireless iFlex AC Current Module TL175 Test Leads AC175 Alligator Clips iFlex i2500-10 Flexible Current Probe Manuals a3001 FC | Quick reference guide a3001 FC | Safety sheet a3001 FC | Safety sheet supplement a3001 FC | Calibration manual Data Sheets Fluke 3000 FC DMM Data Sheet