3KW 48V Hybrid Pure Sine Wave MPPT Solar Inverter, 48V DC to 240V AC, Off Grid Tie

3KW 48V Hybrid Pure Sine Wave MPPT Solar Inverter, 48V DC to 240V AC, Off Grid Tie

$400.00
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

3KW 48V Hybrid Pure Sine Wave MPPT Solar Inverter,48VDC to 240VAC Off-grid tie Pure sine wave inverter Built-in MPPT solar charge controller Selectable input voltage range for home appliances and personal computers Selectable charging current based on applications Configurable AC/Solar input priority via LCD setting Compatible with mains voltage or generator power Auto restart while AC is recovering Overload and short-circuit protection Smart battery charger design for optimized battery performance Cold start function     Model 3KVA-48-120 Photovoltaic Side Input   Photovoltaic input voltage range 110-450VDC Maximum input voltage 450VDC Maximum input power of photovoltaic system  3000W Maximum photovoltaic charging current 100A Storage Battery Pattern Pb/Li Rated Input Voltage 48VDC Direct Cell Voltage Range 46.4-58.8V(Li),38.4-60V(Pb) Maximum Charging Current  130A Floating Impulse Voltage 53.5V(Pb),Li batteries are determined by the user Average Charging Voltage 56.5V(Pb),Li batteries are determined by the user Waveform Pure sine wave Equipment Protection Battery overvoltage protection Yes overload protection  Yes Short Circuit Protection Yes Over Temperature Protection  Yes Basic Parameters Dimensions   380/252/103mm Net Weight 6.3kg Noise ≤48dB Use Temperature Range -20℃~+55℃ Storage Temperature  -15℃∽+60℃ Use Humidity Range 0~90%  No condensation Standby Power Consumption 11W Using altitude ≤6000m  AC Side Input Rated Voltage 230VAC Voltage Range 170-270Vac(UPS), 90-280Vac(APL) Maximum Input Voltage  280VAC Rated Input Frequency 50Hz/60Hz(self-adaption ) Frequency Range 40-65Hz Conversion Range 10ms(UPS) 20ms(APL) Maximum AC Charging Current 60A Inverter Output Parameters Rated Output Capacity 3KW Rated Output Voltage  230VAC/208VAC/240VAC Voltage Accuracy  ±5%  Rated Output Frequency 50Hz/60Hz Frequency Accuracy ±2% Output Waveform Distortion Rate (THD) ≤3%(100%Linear Load ) Power Factor 1.0 Maximum Efficiency 95.5%(PV360V@1/2load) Mixed Network Output Overload Current 20A Off grid carrying capacity 110%<load<150%  (±10%): 10s after Alarm shutdown; 150%<load<200%  (±10%): 5s after Alarm shutdown; 200%<load (±10%): Immediate alarm shutdown;   Please download the PDF manual from here.   Reminder: The US warehouse only ships to USA addresses. The DE warehouse only ships to European Union addresses. The AU warehouse only ships to  Australian addresses. The CN warehouse can ship to the world.

Show More Show Less