ACiQ 5 Ton 17.5 SEER2 High Efficiency Central Heat Pump System | Inverter | Extreme+ Series - R454B

ACiQ 5 Ton 17.5 SEER2 High Efficiency Central Heat Pump System | Inverter | Extreme+ Series - R454B

$6,232.00
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

ACiQ 5 Ton 17.5 SEER2 High Efficiency Central Heat Pump System | Inverter | Extreme+ Series - R454B Overview ACiQ's Extreme+ heat pump systems provide a level of comfort that is rivaled by none - a high-performance, self-adjusting, mini-split-style inverter condenser matched to a communicating air handler that will attach seamlessly to your existing ductwork for easy installation. Product Features Complete all-electric heating and cooling system Pre-charged with R454B refrigerant High efficiency inverter technology reduces energy bills Can be installed in upflow, downflow, or horizontal applications Well-suited for large homes in various climates Hyper heat to provide efficient heat down to -22°F How is it different from other heat pumps? Traditional heat pumps rely on expensive heat strips below 30°F ACiQ Extreme+ heat pumps save up to 75% in temps below 30°F Extreme+ heat pump systems provide the best possible performance regardless of climate Variable BTU inverter ramps up and down to match demand Smart system with soft startups to maximize efficiency OK to size for heat - will not short cycle during cooling Extreme Heat technology keeps you warm to -22°F and beyond Slim-fit air handler provides more flexibility in installation ACiQ 5 Ton 16 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series - R454B Overview Inverter - The ACiQ-60-HPD 5 ton Extreme series central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor inside your condenser to speed up and slow down. This allows the system to self-adjust BTU output based on demand. As the weather changes, so will your system output. Learning Condenser - Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode that optimizes future operations for maximum efficiency by collecting and storing data. Adaptive Sizing - With its self-adjusting inverter design, the ACiQ-60-HPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity. Extreme Heat Technology - "Extreme Heat" means extended temperature range heating all the way down to -22°F. Traditional heat pumps cannot produce significant heat below about 30°F outside temperature. Below that threshold, they rely on expensive backup electric heat. The ACiQ-60-HPD uses the inverter to vary the refrigerant flow, allowing for maximum heat extraction during extreme cold temperatures. The backup electric heat supplements the heat pump, and only takes over below -22°F. The heat pump gives 100% at 0°F, and still gives 80% at -22°F, saving you up to 75% on cold weather heating bills. Quick Facts: Variable BTU output based on demand: 12,000-54,000 BTU for cooling, 12,000-56,000 for heating R454B refrigerant Inverter heat pump system for ducted applications Efficient cooling from -22°F to 122°F outdoor temperatures Efficient heating from -22°F to 75°F outdoor temperatures Durable gold fin condenser coil coating for longevity Quiet operation, even under high workloads 5 Ton, 16 SEER2 Boasting an efficiency rating of 16 SEER2, the ACiQ-60-HPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency. Extreme Heat Base Pan Heater Technology Each ACiQ condenser has integrated Extreme Heat technology to maximize heat performance in extreme cold weather. Extended heat pump performance (HyperHeat) harnesses the power of inverter condenser with outdoor temp sensing, variable refrigerant flow and variable condenser fan speed to maximize heat extraction all the way down to -22°F. Plus, every Extreme Heat ACiQ condenser includes a base pan heater to keep ice from collecting on the condenser coil during heat pump operation. Quality Construction State-of-the-Art manufacturing is behind every ACiQ product, resulting in quiet, effective operation over a long service life. Most models have low ambient heating and cooling. Highest Efficiency ACiQ saves you money up front, but also over time by reducing energy bills. Every ACiQ condenser features a variable inverter twin rotary compressor, lowering wear and increasing performance. Compare specs against other brands in the same price category, and you will agree, ACiQ is the best value. Longer life, longer warranty Intelligent design goes into every element of ACiQ’s manufacturing ensuring flawless performance for years. Low friction, variable inverter twin rotary compressors give bulletproof reliability. Register equipment at ACiQ.com to extend warranty protection to 7 years parts, 12 years compressor.   ACiQ 5 Ton Extreme+ Ducted Air Handler - R454B Redefining Comfort with Extreme+ Efficiency The ACIQ-60-PAH Extreme+ ducted air handler is one of the best multi-positional air handlers on the market today. Featuring a variable speed DC blower, communicating technology, and the best possible performance in any climate, comfort and efficiency levels hit extreme peaks well above the standard maximums from other typical air handlers. Your thermostat communicates with the inverter condenser outside and this air handler inside, telling the system when to self-adjust its BTU output in order to maximize efficiency while providing your desired level of comfort. 5 ton high efficiency central ducted air handler Compatible with any 24v thermostat Variable speed DC blower Multi-positional - Can be installed in upflow, downflow, or horizontal left/right orientations Slim-fit cabinet size for easier installation Higher-performance capabilities leading to better tax credit and rebate eligibility Compatible with R454B refrigerant Installation and Maintenance Installation is very similar to installing any replacement air handler. Your technician will make electrical, refrigerant, thermostat, and communication connections as well as connect the air handler to your return and supply ductwork. The ACiQ Extreme+ central ducted air handler is multi-positional (upflow, downflow or horizontal) and utilizes a narrower cabinet than other air handlers, making it a very versatile, easy-to-install air handler. Any 24v thermostat with 2 stages of heating can control the system. Supplemental electric heat kits are available as a backup heat source for the coldest days of the year. If any maintenance is required, the intelligent control board in the air handler displays fault codes in case any part of the system experiences issues. Please note - in order to function, this air handler must be installed with a condenser and other installation equipment, available at an additional cost if not already included in this product bundle. To use straight electric heating, an electric heat kit is necessary and is also available at an additional cost. Heat Pump Condenser Specifications: Brand ACiQ SKU ACiQ-60-HPD Refrigerant Charge 25' Weight 275.130000 Replaces ACiQ-60-HPB Product Features Inverter, Low Ambient Heating, Two Stage Condenser, Variable Speed Condenser HSPF2 9.0 Cooling BTU 55,000 BTU Heating BTU 59,000 BTU Maximum CFM 1807 Decibel Level (dBA) 65 Electric Heat Heat Pump Refrigerant R454B SEER2 16 Condenser Stages Variable Speed Compressor Type Rotary Liquid Valve Size 3/8" Suction Valve Size 3/4" Electrical 208/230V 1 Phase 60 Hz Max Breaker Size 40 Amps Min. Breaker Size 40 Amps Tonnage 5 Ton BTU/Tonnage 60,000 BTU/5 Ton Min/Max Outdoor Temp for Heating -22°F - 75°F Min/Max Outdoor Temp for Cooling -22°F - 122°F Ambient Temperature Range -22°F - 122°F Height 58.3" Width 37.5" Depth 16.3" Warranty 12 Years Compressor and 7 Years Parts with Online Registration Resources HPD Installation Manual HPD Service Manual Safety Information Proposition 65 Warning Air Handler Specifications: Brand ACiQ SKU ACiQ-60-PAH Weight 188.050000 Cooling BTU 54,000 BTU Maximum CFM 1801 Decibel Level (dBA) Up to 60 Decibels Electric Backup Heat Capabilities (Optional) 5 Kilowatts, 8 Kilowatts, 10 Kilowatts, 15 Kilowatts, 20 Kilowatts Configuration Multi-Positional Refrigerant R454B Liquid Line 3/8" Suction Line 3/4" Electrical 208/230V 1 Phase 60 Hz Max Breaker Size 15 Amps Min. Breaker Size 14.5 / 10.0 Amps Tonnage 5 Ton BTU/Tonnage 60,000 BTU/5 Ton Mini Split Type Multi-Positional Zone Compatibility Single Zone Connection Flared Height 56" Width 24.5" Depth 21.5" Warranty 12 Years Compressor and 7 Years Parts with Online Registration Resources PAH Installation Manual PAH Owner's Manual 5 Ton HPD / PAH Submittal Safety Information Proposition 65 Warning

Show More Show Less