H3C S6300-52QF Series Data Center Switches Ethernet switch

H3C S6300-52QF Series Data Center Switches Ethernet switch

$7,150.00

Quick Details Products Status:Stock Ports:≥ 48 Transmission Rate:10/100/1000Mbps Function:QoS Certification:RADIUS Switch Capacity:1.28Tbps Brand Name:H3C Model Number:LS-6300-52QF Place of Origin:Guangdong, China Warranty:1year Dimensions (W x D x H):440*660*43.6mm Packaging & Delivery Packaging Details:1.Anti-static bag for each hdd.                                2.each goods use Foam buffer protect from friction                                3.The goods be packed very well ,can ship to all over the world Port:HongKong Lead Time : Quantity(Pieces) 1 - 1 >1 Est. Time(days) 30 To be negotiated Product Description Features S6300-52QF S6300-48S S6300-42QF S6300-42QT Dimensions (W × D × H) 440×460×43.6mm 440×460×43.6mm 440×460×43.6mm 440×660×43.6mm Weight ≤10kg Flash/SDRAM 512MB/2GB Console port 1 Ethernet port for management 1 USB port 1 10G Base-T port 0 32 SFP Plus 48 40 8 QSFP(40GE) 4 0 2 2 Input Voltage AC:Rated voltage range: 100V to 240V AC,50/60Hz Maximum voltage range: 90V to 264V AC, 47/63Hz DC:Rated voltage range: -40V to -60V DC;Maximum voltage range: -40V to -72V DC Fan Hot-swappable fan, fan speed adjustableand wind invertible Power consumption(in full configuration) 250W 230W 240W 370W Operating temperature 0ºC~45ºC Operating relative humidity(non-condensing) 10%~90% Port Switching Capacity 1.28Tbps 0.96Tbps 0.96Tbps 0.96Tbps Forwarding performance 960Mpps 720Mpps 720Mpps 720Mpps Forwarding mode Store-forward and cut-through Horizontal Virtualization Intelligent Resilient Framework 2 (IRF2)Distributed device management, distributed link aggregation, distributed resilient routingStacking through standard Ethernet portLocal and remote stackingLACP, BFD and ARP based MAD stacking collision inspection mechanism Link aggregation 10GE port aggregation40GE port aggregationstatic aggregation, dynamic aggregation Data center features VEPA 802.1Qbg802.1Qbb PFC, 802.1Qaz ETS, ECNFCoE Packet Transparent Pass throughT11 standards-compliant FCoE (FC-BB-5)Fibre Channel forwarding (FCF)N-Port Virtualization (NPV) technologyN-port identifier virtualization (NPIV)Standard zoningFibre Channel pingTRILLTRILL & IRF Jumbo Frame Support MAC address table Static MAC addressBlackhole MAC addressCan configure maximum number of port MAC address VLAN Port-based VLAN (4094 items)Default VLANQINQ and Flexible QINQVLAN MAPPINGPVST+, RPVST+ Traffic monitoring Support sFlow DHCP DHCP ClientDHCP SnoopingDHCP RelayDHCP ServerDHCP Snooping option82/DHCP Relay option82 ARP Static table entryGratuitous ARPStandard proxy ARP and local proxy ARPDynamic ARP InspectionARP anti-attackARP source suppressionARP Detection function (check according to DHCP Snooping safety entry, 802.1x table entry or IP/MAC static binding table entry) Routing IPv4, IPv6 Static routing, RIP v1/2 and RIPngECMP, VRRP, OSPFv1/v2/v3, BGP Multicast protocol IGMP Snooping v2/v3IGMP Snooping Fast-leaveIGMP Snooping Group-policyPIM snoopingMSDPMVRPMFFIPv6 PIM snooping, IPv6 multicast VLAN, IPv6 PIM Zero configuration Zero-touch configuration based on DHCPAuto-config or CWMP-TR069 Broadcast / Multicast / Unicaststorm suppression Port rate percentage basedPPS-basedBPS-based MSTP STP/RSTP/MSTPSTP Root GuardRoot Protection, Loop Protection, Edge Port/BPDU GuardBPDU Guard QoS/ACL Flow controlCommitted Access Rate (CAR)8 output queues per portFlexible queue scheduling algorithm can be set based on port and queue, support SP, WDRR, WRR, WFQ, SP + WDRR and other models802.1p and DSCP priority re-markingL2 (Layer 2) ~ L4 (Layer 4) packet filtering based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address,destination IP (IPv4/IPv6) address, port, protocol, and VLAN Traffic ClassificationTime range Mirror Flow MirroringN: 4 port mirroringLocal and remote port mirroring Security features Hierarchical user management and password protectionARP packet rate limit, ARP attack protectionCentralized MAC authentication802.1XStorm constrainAAA authenticationRADIUS authenticationHWTACACSSSH 2.0Port isolationIP + MAC + port bindingIP Source GuardHTTPsSSLPublic Key Infrastructure (PKI) Firmware upgrade Upgrade via the XModem, File Transfer Protocol (FTP) and Trivial File Transfer Protocol (TFTP) Management and maintenance Configuration via CLI, Telnet, and Console portSchedule jobISSU802.1ag and 802.3ahSNMPv1/v2c/v3(Simple Network Management Protocol)H3C Intelligent Management Centre (iMC)System loghierarchical alarmNTPPower, fan and temperature alarmsDebug string outputPing, TracertTrackTelnet remote maintenanceCopy switch files to and from a USB flash drive EMC FCC Part 15 Subpart B Class AICES-003 CLASS AVCCI CLASS ACISPR 22 CLASS AEN 55022 CLASS AAS/NZS CISPR22 CLASS ACISPR 32 CLASS AEN 55032 CLASS AAS/NZS CISPR32 CLASS ACISPR 24EN 55024EN 61000-3-2EN 61000-3-3ETSI EN 300 386GB/T 9254YD/T993 Safety UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1AS/NZS 60950-1FDA 21 CFR Subchapter JGB 4943.1 High-Density 10GE Ports As client side network bandwidth grows, 10GE adapters are increasingly common in servers, switches have to deliver a higherforwarding performance and provide more 10GE expansion space. S6300-52QF features 48 SFP+ optical ports and 4*40G QSFP ports,S6300-42QF features 40 SFP+ optical ports, and 2*40G QSFP ports, S6300-48S features 48 SFP+ optical ports and S6300-42QT features32 10G Base-T ports, 8 SFP+ optical ports and 2*40G QSFP ports. Each 40G QSFP port can run as a single 40G port or 4 10GE portswith conversion cables. Intelligent Resilient Framework 2 (IRF2) S6300 series is pre-built with Intelligent Resilient Framework 2 (IRF2). IRF2 provides the following benefits: High scalability: With IRF2, plug-n-play device aggregation can be achieved by adding one or more switches into the IRF2 stackand enabling IRF2 stacking on the new device. New devices can be managed with a single IP, and upgraded at the same time to reducenetwork expansion cost. High reliability: The IRF2 patented 1:N backup technology allows each slave device in the IRF2 stack to serve as the backup ofthe master, creating control and data link redundancy, as well as uninterrupted layer-3 forwarding. This improves the reliability,avoids unplanned business downtime and serves to improve overall performance. When the master device fails, traffic remainsuninterrupted. Load balancing: IRF2 supports cross-device link aggregation, upstream and downstream can be connected to more than one physicallink, which creates another layer of network redundancy and boosts the network resource utilization. Availability: H3C Implements IRF2 through standard Forty Gigabit Ethernet (40GE) or Ten Gigabit Ethernet (10GE) ports whichallocates bandwidth for business and application access and reasonably splits local traffic and upstream traffic. IRF2 rules cannot only be obeyed within and across the rack, but also across the LAN. Data Center-Oriented Features S6300 series adopts the modular dual power supply and dual fans design, both supporting hot plug-in and pull-out. With themodular software platform, the software function modules can be added and deleted flexibly according to requirements. Throughexquisite physical structure and software process optimization, the end-to-end packet processing latency is greatly reduced, whichis on 10GE/40GE ports less than 1us, 20% less than average in the industry. S6300 series supports EVB (Edge Virtual Bridging) and uploads data traffic generated on VMs (Virtual Machines) to switchesconnected with servers for processing via VEPA (Virtual Ethernet Port Aggregation), not only forward traffic between VMs, butsolve problems of connection and management boundary between VMs and network. FCoE technology leverages Ethernet packet to carry FC traffic, so that FC SAN can share the same network with Ethernet LAN tosolve coexistence problems of different types of networks. S6300 switch series supports full FCoE and FC protocol stack. TRILL (Transparent Interconnection of Lots of Links) is an innovative technology that changes the traditional way to build datacenter networks. It introduces benefits of layer 3 routing technology, such as stable, scalable and high performance into layer 2switching network (traditional limited performances and network scenario) to make Layer 2 network more flexible, extensible, andhigh-performance. It is an ideal choice for S6300 switch series with TRILL to build a large scale, high-performance, andextensible cloud Data Center networks that which supports VMs dynamic migration. SDN (Software Defined Network) is an innovative network framework that simplifies network management and reduces maintenancecomplexity with the core technology of OpenFlow which separates control plane from forwarding layer. It also controls trafficflexibly and provide a well-defined network platform for core network application and innovation. S6300 switch series supports DCB (Data Center Bridging), ISSU (In-service Software Upgrade), OAM (Operations, Administration andMaintenance) and Energy-Efficient Ethernet (EEE). It fully satisfies Data Center’s requirements of high performance, easymanagement and green energy saving. Flexible Choice of Airflow To cope with data center cooling aisle design, H3C S6300 series comes with flexible airflow design, which features bi-coolingaisles in front and back. Users may also choose the direction of airflow (from front to back or vice versa) by selecting adifferent fan tray. Outstanding Security Control Policies H3C S6300 series supports AAA, RADIUS and user account based authentication, IP, MAC, VLAN, port-based user identification,dynamic and static binding; when working with the H3C iMC platform, it can conduct real time management, instant diagnosis andcrackdown on illicit network behavior. H3C S6300 series supports enhanced ACL control logic, which supports an enormous amount of in-port and out-port ACL, and delegateVLAN based ACL. This simplifies user deployment process and avoids ACL resource wastage. Multiple Reliability H3C S6300 series provides multiple reliability functions at both box and link levels, with over current, overvoltage, andoverheat protection. All models have a redundant pluggable power module, which enables flexible configuration of AC or DC power modules based onactual needs. The entire switch supports fault detection and alarm for power supply and fan, allowing fan speed to change to suitdifferent ambient temperatures. Excellent Manageability H3C S6300 series supports rich management interfaces, including console, out of band management and USB Management protocols suchas SNMPv1/v2/v3, iMC Intelligent Management Center) also supported. The network administrator may activate control through CLI,Web interface and TELNET which gives maximum flexibility in accessing and managing the device. SSH2.0 and SSL encryption can alsobe used to protect the management session. Our Certificates Product packaging 1. DHL / UPS / FedEx / TNT , Door-to-Door.  2. By Air or by Sea , for FCL; Airport/ Port receiving. 3. Customers Specifying Freight Forwarders or Negotiable Shipping Methods. We will choose the best and safe packaging material to make sure your orders won't bedamaged during delivery.

Show More Show Less