
H3C S6800-54QF 48 port Series Data Center Switches ethernet switches
Quick Details: Products Status:Stock Transmission Rate:10/100/1000Mbps Function:QoS Communication Mode:Full-Duplex Certification:RADIUS Switch Capacity:1.44Tbps Brand Name:H3C Model Number:S6800-54QF Place of Origin:Guangdong, China Warranty:1year Dimensions (W x D x H):440*400*44mm Packaging & Delivery: Packaging Details:1.Anti-static bag for each hdd. 2.each goods use Foam buffer protect from friction 3.The goods be packed very well ,can ship to all over the world Port: HongKong Lead Time : Quantity(Pieces) 1 - 1 >1 Est. Time(days) 30 To be negotiated Product Description: Features S6800-32Q S6800-54QF S6800-54QT S6800-2C S6800-4C Dimensions(W × D × H) 440×660×43.6 440×400×44 440×460×44 440×660×44.2 440×660×88.1 Weight ≤13kg ≤13kg ≤13kg ≤16Kg ≤27Kg Console port Console :1; Mini USB Console: 1 Flash/Memory 1GB/4GB Ethernet port for management 1 10M/100M/1000MBase-T: 1SFP 1000Base-X: 1 1 1 USB port 1 1/10G Base-T port / / 48 / / 1/10G SFP+ port / 48 / / / QSFP port 32 6 6 2 / QSFP28 port / Module slot / 2 4 Input Voltage –AC Related voltage range: 100V to 240V AC, 50/60Hz Maximum voltage range: 90V to 290V AC Input Voltage –DC Related voltage range: -38.4V to -72V DC Power module Two Four Fan Two hot-swappable fan,fan speed adjustable and wind invertible Three hot-swappable fan,fan speed adjustable and wind invertible Five hot-swappable fan,fan speed adjustableand wind invertible Two hot-swappable fan, fan speed adjustable and wind invertible Power consumption(idle) Single AC: 132WDual AC: 145WSingle DC: 128WDual DC: 142W PSR250-12APSR250-12A1:Single AC:65WDual AC:71WPSR450-12A1:Single AC:68WDual AC:79WPSR450-12D:Single DC:67WDual DC:76W PSR450-12A1:Single AC:103WDual AC:109WPSR450-12D:Single DC:107WDual DC:113W Single AC: 95WDual AC: 110WSingle DC: 91WDual DC: 105W Dual AC: 135WThree AC: 150WFour AC: 165WDual DC: 131WThree DC: 145WFour DC: 155W Power consumption(fully loaded) Single AC: 291WDual AC: 301WSingle DC: 291WDual DC: 299W PSR250-12A/PSR250-12A1:Single AC:165WDual AC:175WPSR450-12A1:Single AC:166WDual AC:175WPSR450-12D:Single DC:166WDual DC:171W PSR450-12A1:Single AC:103WDual AC:109WPSR450-12D:Single DC:107WDual DC:113W Single AC:439WDual AC: 450WSingle DC:443WDual DC: 445W Dual AC: 827WThree AC: 837WFour AC: 856WDual DC: 823WThree DC: 825WFour DC: 828W Operating temperature 0℃~45℃ Operating relativehumidity 10%~90% Port SwitchingCapacity 2.56Tbps 1.44Tbps 1.44Tbps 1.44Tbps 2.56Tbps Forwardingperformance 1440Mpps 1080Mpps 1080Mpps 1080Mpps 1440Mpps Forwarding mode Store-forward and cut-through Virtualization Intelligent Resilient Framework 2 (IRF2)Distributed device managementStacking through standard Ethernet portLocal and remote stackingLACP, BFD, ARP and MAD based stack collision Link aggregation 10GE port aggregation40GE port aggregationStatic aggregation, dynamic aggregationLink cross board aggregation, cross device link aggregation M-LAG Data center features VXLAN L2 switchingVXLAN L3 routingVXLAN VTEPMP-BGP+EVPN distributed control plane802.1Qbb PFC, 802.1Qaz ETS, ECNFCoE and FC protocol stackFC/FCoE/Ethernet multiplexing portsTRILLTRILL & IRFSPBOpenFlow1.3.1Netconf , PythonService chainMultiple OpenFlow controller Jumbo Frame √ MAC address table Static MAC addressBlackhole MAC address VLAN Port-based VLAN (4094)Default VLAN Traffic monitoring sFlow DHCP DHCP Server/ClientDHCP SnoopingDHCP RelayDHCP Snooping option82/DHCP Relay option82 ARP Static table entryGratuitous ARPDynamic ARP InspectionARP anti-attackARP source suppressionARP Detection function (check according to DHCP Snooping safety entry, 802.1x table entry or IP/MAC static binding table entry) IPv4 routing Static routing, RIP v1/2, OSPFv1/v2/v3, BGP, IS-ISEqual-Cost Multi-Path routing (ECMP), VRRP, policy-based routing IPv6 routing RIPng, OSPF v3, IS-IS v6BGP4 + for IPv6, VRRP, IPv6 routing strategyND (Neighbor Discovery)PMTUICMP v6, Telnet v6, SFTP v6, SNMP v6, BFD v6, VRRP v3IPv6 PortalIPv6 tunnel Multicast protocol IGMP Snooping v2/v3IGMP v1/v2/v3PIM-DM/SMIPv6 PIM-DM/SM/SSMPIM, MSDPMLD SnoopingMulticast policy Zero configuration Auto-config and Configure Rollback MPLS MCEMPLS VPN and VPLS MSTP STP/RSTP/MSTPPVST+/RPVST+STP Root GuardBPDU Guard QoS/ACL Flow controlCommitted Access Rate (CAR)Eight output queues per portFlexible queue scheduling algorithm can be set based on port and queue, support SP, WRR, WFQ, SP + WRR, SP + WFQ and other models802.1p and DSCP priority re-markingL2 (Layer 2) ~ L4 (Layer 4) packet filtering based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address,destination IP (IPv4/IPv6) address, port, protocol, and VLAN Traffic ClassificationTime rangeWeighted Random Early Detection (WRED) Mirror Flow MirroringN: 4 port mirroringLocal and remote port mirroring Security Hierarchical user management and password protectionAAA authentication supportRADIUS authenticationHWTACACSSSH 2.0IP + MAC + port bindingIP Source GuardHTTPsSSLPublic Key Infrastructure (PKI) Firmwareupgrade Upgrade via the XModem, File Transfer Protocol (FTP) and Trivial File Transfer Protocol (TFTP) Managementand maintenance Configuration via CLI, Telnet, and Console portSchedule jobISSUSNMP(Simple Network Management Protocol)H3C Intelligent Management Centre (iMC)System logHierarchical alarmNTPPower, fan and temperature alarmsDebug string outputPing, TracertTrackTelnet remote maintenanceCopy switch files to and from a USB flash drive EMC FCC Part 15 Subpart B CLASS AICES-003 CLASS AVCCI CLASS ACISPR 32 CLASS AEN 55032 CLASS AAS/NZS CISPR32 CLASS ACISPR 24EN 55024EN 61000-3-2EN 61000-3-3ETSI EN 300 386GB 9254YD/T993 Safety UL 60950-1CAN/CSA C22.2 No 60950-1IEC 60950-1EN 60950-1AS/NZS 60950-1FDA 21 CFR Subchapter JGB 4943.1 Flexible port combination As network bandwidth tremendously grows, 10GE adapters are increasingly common in servers. The need of delivering high forwardingperformance and providing more 10/40/100 GE expansion space has become essential.H3C S6800-4C is built to cope with the need providing four module slots, and supporting high density 10G SFP+ fiber, 1/10G Base-Tcopper and 40G QSFP+ flexible configuration combination. The S6800-4C can also support a maximum of 96 10G and 8 40G ports, or 3240G ports and can even support 96 FC/FCoE/Ethernet universal ports through its flexible FC interface module.H3C S6800-2C can support a maximum of 48 10G and 6 40G ports or 18 40G ports. Through its flexible FC interface module, S6800-2Ccan even support 48 FC/FCoE/Ethernet universal ports.For 100G uplink, the S6800-54HF/HT can support fixed 48 10G Base-X or Base-T and 6 100G QSFP28 ports.For 40G uplink, the S6800-54QF/QT can support fixed 48 10G Base-X or Base-T and 6 40G QSFP28 ports.S6800-32Q features 32*40G QSFP+ port, via 40G to 10G cable, supporting a maximum 104 10G ports. Intelligent Resilient Framework 2 (IRF2) H3C S6800 switch series is pre-built with Intelligent Resilient Framework 2 (IRF2). IRF2 provides the following benefits:High scalability: With IRF2, plug-n-play device aggregation can be achieved by adding one or more switches into the IRF2 stackand enabling IRF2 stacking on the new device. New devices can be managed with a single IP, and upgraded at the same time to reducenetwork expansion cost.High reliability: The IRF2 patented 1:N backup technology allows each slave device in the IRF2 stack to serve as the backup ofthe master, creating control and data link redundancy, as well as uninterrupted layer-3 forwarding. This improves the reliability,avoids unplanned business downtime and serves to improve overall performance. When the master device fails, traffic remainsuninterrupted.Load balancing: IRF2 supports cross-device link aggregation, upstream and downstream can be connected to more than one physicallink, which creates another layer of network redundancy and boosts the network resource utilization.Availability: H3C Implements IRF2 through standard Forty Gigabit Ethernet (40GE) or Ten Gigabit Ethernet (10GE) ports whichallocates bandwidth for business and application access and reasonably splits local traffic and upstream traffic. IRF2 rules cannot only be obeyed within and across the rack, but also across the LAN. Data Center-Oriented Features FCoE (Fiber Channel over Ethernet) technology leverages Ethernet packet to carry FC packets. This means FC SAN and Ethernet LANnetwork can share the same network infrastructure, which is a good solution to solve the problems of coexistence between differenttypes of network. S6800 switch series supports full FCoE and FC protocol stack. All downstream SFP + ports can be switched to FCport to interoperate with FC SAN. As the FC SAN and Ethernet network are fully integrated, the entire network infrastructure isgreatly simplified.TRILL (Transparent Interconnection of Lots of Links) is an innovative technology that changes the traditional way to build datacenter networks. It incorporates the benefits of layer 3 routing technology, such as stable, scalable and high performance into anadaptable, but limited scope of layer 2 switching network. The end result is flexible, extensible, high-performance layer 2network architecture. By using TRILL technology, S6800 switch series becomes the ideal choice to build a large, high-performance,and scalable cloud data center networks that support live virtual machines.SDN (Software Defined Network) is an innovative network architecture that simplifies network management and reduces maintenancecomplexity. This is accomplished by separating network control layer and network forwarding layer through OpenFlow. Moreimportantly, it implements flexible network flow control and provides a well-defined network platform for core network applicationand innovation.H3C S6800 switch series supports DCB (Data Center Bridging), ISSU (In-service Software Upgrade), OAM (Operations, Administrationand Maintenance) and EEE (Energy-Efficient Ethernet) . It fully meets the high performance data center requirements, and is easyto manage with green energy consumption.H3C S6800 switch series supports VXLAN (Virtual Extensible LAN), VXLAN uses a MAC-in-UDP encapsulation method where the originalLayer 2 package is added a VXLAN header, and is then placed in a UDP-IP packet. With the help of MAC-in-UDP encapsulation, VXLANtunnels Layer 2 network over Layer 3 network. This provides two major benefits, higher scalability of Layer 2 segmentation andbetter utilization of available network paths.H3C S6800 switch series supports MP-BGP EVPN (Multiprotocol Border Gateway Protocol Ethernet Virtual Private Network) usesstandard-based BGP protocol as the control plane for VXLAN overlay networks, providing BGP based VTEP auto peer discovery andend-host reachability information distribution. MP-BGP EVPN delivers many benefits, such as eliminating traffic flooding, reducingfull mesh requirements between VTEPs via the introduction of BGP RR, achieving optimal flow based end to end load sharing andmore.H3C S6800 switch series supports the intelligent caching technology. Its hardware implements intelligent distribution of trafficload, while utilization ratio increases up to five times than traditional method. In addition, S6800 employs intelligent hardwareentry technology to achieve MAC/ARP/IP routing FIB table adjusts dynamically, and entry specification (such as MAC maximum up288K) increased by 10 times compared with traditional switches. S6800 also supports intelligent hash technology. Under heavynetwork traffic, it can significantly eliminate network polarization and load imbalances. S6800 switch series useshigh-performance multi-core CPU architecture and modular software operating platform to achieve greater flexibility whenscheduling tasks with different priorities. Flexible choice of airflow To cope with data center cooling aisle design, the H3C S6800 switch series comes with flexible airflow design, which featuresbi-cooling aisles in the front and back. Users may also choose the direction of airflow (from front to back or vice versa) byselecting a different fan tray. Outstanding security control policies H3C S6800 switch series supports AAA, RADIUS and user account based authentication, IP, MAC, VLAN, port-based useridentification, dynamic and static binding; when working with the H3C iMC platform, it can conduct real time management, instantdiagnosis and crackdown on illicit network behavior.H3C S6800 switch series supports enhanced ACL control logic, which enables an enormous amount of in-port and out- port ACL, anddelegate VLAN based ACL. This simplifies user deployment process and avoids ACL resource wastage. S6800 switch series can alsotake advantage of Unicast Reverse Path Forwarding (Unicast RPF). When the device receives a packet, it will perform the reversecheck to verify the source address from which the packets are supposedly originated, and will drop the packet if such path doesn’texist. This will curb the increasingly common originating address spoofing. MACsec H3C S6800 switch series supports hardware level encryption technology MACsec (802.1ae), which is an industry-standard securitytechnology that provides secure communication for all traffic on Ethernet links. Compared with traditional application basedsoftware encryption technology, MACsec provides point to-point security on Ethernet links between directly connected nodes and iscapable of identifying and preventing most security threats. Multiple Reliability H3C S6800 switch series provides multiple reliability protection at both switch and link levels. With overcurrent, overvoltage,and overheat protection, all models have a redundant pluggable power module, which enables flexible configuration of AC or DCpower modules based on actual needs. The entire switch supports fault detection and alarm for power supply and fan, allowing fanspeed to change to suit different ambient temperatures. Excellent manageability H3C S6800 switch series provides a rich management interface, including console, external network and USB. Management protocolssuch as SNMPv1/v2/v3 are supported aside from iMC Management Console. The network administrator may activate control through CLI,Web interface and TELNET which gives maximum flexibility in accessing and managing the device. The administrator may also chooseSSH2.0 and SSL encryption to shield the management session. Packing & Delivery: 1. DHL / UPS / FedEx / TNT , Door-to-Door. 2. By Air or by Sea , for FCL; Airport/ Port receiving. 3. Customers Specifying Freight Forwarders or Negotiable Shipping Methods. We will choose the best and safe packaging material to make sure your orders won't bedamaged during delivery. Company Profie: TFC is one-stop supplier for quality new, used and refurbished IT hardware. NMI buys, sells, leases, rents, consigns and tradesjust about every product line including Sun, HP, IBM, Dell,Lenovo, storage equipment as NetApp and EMC, telecom equipment asH3C,HUAWEI,CISCO,Juniper etc... Our Certificates: FAQ: Q1:What's your main product? TFC mainly produce networking equipment, server , storage equipment etc.Q2:What's your payment term?Usually L/C,T/T,D/P,D/A ,it is determined by our negotiation.Q3:Can you customize product?Yes, TFC can supply you products according to your requirement .Q4:What is the MOQ and Leading?Usually 30~50 working days for delivery.