
Autonics TMH4-N2SB Modular 4CH Temperature Controller Basic Module SSR Output
Advanced Multi-Channel Modular Temperature Controller, 4 channel, CT Input, RS485 Communicate Output, 24VDC, SSR Output, Basic module Number of input channels : 4-channel Power supply : 24VDC Easy maintenance with detachable body and base terminal Power supply and communication with expansion connectors (up to 32 units) Parameter configuration with PCs (USB or RS485 communication) : DAQMaster software provided (comprehensive device management software) *Communication converters sold separately: SCM-US (USB/Serial converter), SCM-38I (RS232C/RS485 converter), SCM-US48I (USB/RS485 converter), SCM-WF48 (Wi-Fi/RS485∙USB wireless communication converter), EXT-US (converter cable) Multi-channel (2-channel/4-channel) input and output control : Expandable up to 32 units (64-channels/128-channels) 50 ms high-speed sampling rate and ±0.3% measurement accuracy Simultaneous heating and cooling control function and auto/manual control mode Switch between current output and SSR drive output Isolated input channels (dielectric strength: 1,000 VAC) Measure load current with CT input terminal (*CT sold separately: CSTC-E80LN, CSTC-E200LN, CSTS-E80PP) Various input types and temperature ranges Allowable voltage range : 90 to 110% of rated voltage Power consumption : Max. 5W(for max. load) Display method : None-parameter setting and monitoring is available at external devices(PC, PLC, etc.) Input type_TC : K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II Input type_RTD : DPt100Ω, JPt100Ω, DPt50Ω, Cu100Ω, Cu50Ω, Nikel 120Ω 3-wire type(permissible line resistance max. 5Ω) Input type_Analog : Voltage: 0-100mVDC , 0-5VDC , 1-5VDC , 0-10VDC Current : 0-20mA, 4-20mA Sampling cycle : 50ms(2-CH or 4-CH synchronous sampling) Measurement accuracy_Thermocouple : At room temperature(23℃±5℃): (PV ±0.3% or ±1℃, higher one) ±1-digit Out of room temperature range : (PV ±0.5% or ±2℃, higher one) ±1-digit Measurement accuracy_RTD : At room temperature(23℃±5℃): (PV ±0.3% or ±1℃, higher one) ±1-digit Out of room temperature range : (PV ±0.5% or ±2℃, higher one) ±1-digit Measurement accuracy_Analog : At room temperature(23℃±5℃): ±0.3% F.S. ±1-digit Out of room temperature range : ±0.5% F.S. ±1-digit Option input_CT input : 0.0-50.0A(primary current measurement range) ※CT ratio=1/1000, Measured accuracy: ±5% F.S. ±1-digitt Control method : ON/OFF control, P, PI, PD, PID control Control output_SSR : Max. 12VDC ±3V 20mA Communication_Comm. terminal : RS485 communication output(Modbus RTU) Communication_PC loader : TTL Hysteresis(adjustable sensitivity) : RTD/Thermocouples: 1 to 100℃/℉ (0.1 to 100.0℃/℉), analog: 1 to 100 digit Proportional band RTD/Thermocouples : 1 to 999℃/℉ (0.1 to 999.9℃/℉), analog: 0.1 to 999.9 digit Integral time : 0 to 9999 sec Derivative time : 0 to 9999 sec Control period : Relay output: 0.1 to 120.0 sec, SSR output: 1.0 to 120.0 sec Manual reset : 0 to 100%( 0.0 to 100.0%) Relay life cycle_Mechanical : Min. 10,000,000 operations Relay life cycle_Electrical : Min. 100,000 operations(250VAC 3A resistance load) Memory Protection : Approx. 10 years(non-volatile semiconductor memory type) Insulation resistance : 100MΩ(at 500VDC megger) Insulation type : Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength : 1,000VAC 50/60Hz for 1 min(between input terminals and power terminals) Vibration 0.75mm amplitude at frequency of 5 o 55Hz (for 1 min) in each X, Y, Z direction for 2 hours Noise immunity : ±0.5kV the square wave noise (pulse width: 1㎲) by the noise simulator Environment_Ambient temperature : -10 to 50℃, storage: -20 to 60℃ Environment_Ambient humidity : 35 to 85% RH, storage: 35 to 85% RH Protection structure : IP20(IEC standard) Accessories : Expansion connector: 1, module lock connector: 2 Approval : CE, UL, KC Weight_Basic module : Approx. 250.4g (approx. 177.3g) ※Thermocouple: Connecting 1 or more expansion module can vary measurement accuracy about ±1℃, regardless of the number of connected expansion module.※Measured accuracy:◎At room temperature (23℃±5℃)• Thermocouple K, J, T, N, E below -100℃, L, U, PLII, and RTD Cu50Ω, DPt50Ω: (PV ±0.3% or ±2℃, higher one) ± 1-digit• Thermocouple C, G and R, S below 200℃: (PV ±0.3% or ±3℃, higher one) ± 1-digit• Thermocouple B below 400℃: there is no accuracy standards.◎Out of room temperature range• RTD Cu50Ω, DPt50Ω: (PV ±0.5% or ±3℃, higher one) ± 1-digit• Thermocouple R, S, B, C, G: (PV ±0.5% or ±5℃, higher one) ± 1-digit• Other blow -100℃: within ±5℃※The weight includes packaging. The weight in parenthesis is for unit only.※Environment resistance is rated at no freezing or condensation.