
2 Channel 120V 220V Wireless Remote Control Switch Kit 2Km 10A (Model: 0020471)
Package Include:1 x Receiver: S2U-AC-ANT31 x Transmitter: CB-21 x User manual Application:It can long range remote control DC and AC equipments, such as illumination, lamp, light, motor, linear actuator, electric solenoid valve, pump, ceiling fan, heater, etc. Feature:Wireless control, easy to install.Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.Universal input: Support 110V AC (110V~120V) used in US, Canada, etc, and 220V AC (220V~240V) used in Germany, UK, France, etc.Relay Output: This receiver is dry relay output; it can be used to operate both DC and AC equipment. The output terminals are NO / NC (normally open / normally closed), serving as a switch. That means you should also connect a separate power supply to equipment.Each channel can work at maximum current 10A.With external antenna, the receiver has a farther working range.The transmitter / remote can control the receiver from any place within a reliable working distance.Wireless RF signal from the transmitter can pass through walls, floors, doors, or windows, but it will lose some operating range.The receiver has reverse voltage protection and overcurrent protection.The receiver can only be triggered by paired transmitters.One or more transmitters / remotes can control one or several receivers simultaneously.Two or more receivers may be used in the same area. Receiver Parameters:Model: S2U-AC-ANT3Operating Voltage: AC110~240V (110V/120V/220V/240V)Output Type: Dry Relay Output (With Normally Open and Normally Closed Terminals)Maximum Load Voltage of Relay: 240VAC or 28VDCMaximum Load Current of Relay: 10A / channelQuiescent Current: ≤6mAChannel: 2 Way3 Selectable Working Modes: Self-locking, Momentary, InterlockingWorking Frequency: 433.92MHzSuitable Wires for Connecting Terminals: 22-12 AWGOperating Temperature: -20 °C ~ +70 °CPCB size: 88 x 80 x 18 mmCase size: 153 x 90 x 55 mm Transmitter Parameters:Model No.: 0021024 (CB-2)Channel/Button: 2Button Symbol: A, BOperating Voltage: 9V (1 x 6F22 -9V battery)Operating Current: 30mAWorking Frequency: 433.92MHzTransmitting Distance: 1000 meters / 3000ft (theoretically)It has an on / off button on the side.Modulation Mode: ASKOperating Temperature: -20 ° C to +70 ° CUnit Size: Unit Size: 135 x 42 x 25 mm Suitable transmitters:The receiver can work with different transmitters. such as model C-2 (100 meters / 300 feet range), CP-2 (500 meters / 1500 feet range), CD-2 (Industrial, 1000 meters / 3000 feet range), and CB-2 (1000 meters / 3000 feet range). Working Range:With a transmitter (such as CB-2) to form a complete set, the maximum working distance can reach 2000 meters in an open ground.The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this maximum working distance. Usage:The receiver can be used to control both DC 0~28V and AC 110~240V equipments.Notice: The receiver is dry relay output, not DC/AC power output. Initial state of relay output terminals: Terminals “COM” and “NO” are Normally Open; Terminals “COM” and “NC” are Normally Closed. Wiring:I) If you want to control a DC 12V lamp, do as following:1) Connect the live wire of AC power supply to the terminal "L/+" of the receiver;2) Connect the neutral wire of the AC power supply to the terminal "N/-" of the receiver;3) Connect the positive pole of DC power supply to the terminal "NO" of the receiver;4) Connect the positive pole of DC lamp to the terminal "COM" of the receiver;5) Connect the negative pole of DC power supply to the negative pole of DC lamp. II) If you want to control an AC 220V lamp, do as following:1) Connect the live wire of AC power supply to the terminal "L/+" of the receiver;2) Connect the neutral wire of the AC power supply to the terminal "N/-" of the receiver;3) Connect the live wire of AC power supply to the terminal "NO" of the receiver;4) Connect one side of AC lamp to the terminal "COM" of the receiver;5) Connect the neutral wire of AC power supply to another side of AC lamp. Setting different control modes:1) Setting Momentary mode: Press the learning button in the receiver 2 times, signal LED continuously flashes 2 times and then goes off.The operation of Momentary mode with the transmitter CB-2:Press and hold the button A on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on.Release the button A: The relay 1 is deactivated, and the connected lamp 1 is turned off.Press and hold the button B on the transmitter: The relay 2 in the receiver is activated, and the connected lamp 2 is turned on.Release the button B: The relay 2 is deactivated, and the connected lamp 2 is turned off. 2) Setting Self-locking mode: Press the learning button in the receiver 3 times, signal LED continuously flashes 3 times and then goes off.The operation of Self-locking mode with the transmitter CB-2:Press the button A on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on.Press the button A again: The relay 1 is deactivated, and the connected lamp 1 is turned off.Press the button B on the transmitter: The relay 2 in the receiver is activated, and the connected lamp 2 is turned on.Press the button B again: The relay 2 is deactivated, and the connected lamp 2 is turned off. 3) Setting Interlocking mode: Press the learning button in the receiver 4 times, signal LED continuously flashes 4 times and then goes off.The operation of Interlocking mode with the transmitter CB-3 (Model: 0021025):Press the button A on the transmitter: The relay 1 in the receiver is activated, and the connected lamp 1 is turned on. The relay 2 is deactivated, and the connected lamp 2 is turned off.Press the button B on the transmitter: The relay 2 in the receiver is activated, and the connected lamp 2 is turned on. The relay 1 is deactivated, and the connected lamp 1 is turned off.Press the button C on the transmitter: The relay 1 and 2 in the receiver are deactivated, the lamps 1 and 2 are turned off. How to pair the transmitter to the receiver:1) Press the learning button once in the receiver, signal LED on the receiver flashes one time and then stays on, this indicates that the receiver enters the learning status.2) Press button A on transmitter, if the signal LED flashes one time, this indicates that the pairing with button A is successful. Then press button B on transmitter, if the signal LED flashes one time, this indicates that the pairing with button B is successful.3) Press the learning button in the receiver again for 1-2 seconds, signal LED turns off, this indicates that the receiver exits the learning status.4) The receiver can learn several transmitters with different codes. How to delete all transmitters codes stored in the receiver:Press the learning button in the receiver 10 times and then release the learning button, signal LED flashes 10 times quickly and then goes off, this indicates that all stored codes have been deleted successfully.