LAMBDA SWS50-5/CO2 Switching Power Supply Output 5Volts, 10Amps
LAMBDA SWS50-5/CO2 specifications Nominal output voltage: 5V Maximum output current: 10A Maximum output power: 50W Efficiency (Typ) (115/230 VAC) (*1): 77/75 Input Voltage Range (*2,3): 85 ~265VAC (47 - 63Hz) or 120 ~ 370VDC Input current (Typ) (115/230 VAC) (*1): 1.2/0.6 A Inrush current (Typ) (*4): 20A at 115VAC,40A at 230VAC, Ta=25 ℃, Cold Start. Output voltage range: 4.5~ 5.5V Ripple and Noise (115/230 VAC) (*1,5): 80 mV Line Regulation (*5,6): 20 mV Load Regulation (*5,7): 50 mV Temperature Coefficient: less than 0.02 %/ ℃ Over Current Protection (*8): 10.5A ~ Over Voltage Protection (*9): 5.75V ~ 6.95V Hold-Up Time (Typ) (115/230 VAC) (*1): 20 ms / 160ms Leakage Current (10*): 1mA Max, 0.3mA (Typ) at 115 VAC/ 0.6mA (Typ) at 230 VAC Series Operation: possible Operating Temperature (11*): -10~+60 ℃ (Refer to Output Derating Curve) Operating Humidity: 30~90%RH (no DEWDROP) Storage Temperature: -30~+85 ℃ Storage humidity: 10-95 % RH (no DEWDROP) Cooling: Convection cooling Withstand Voltage: Input-Output: 3.0kVAC (20mA), input-FG: 2.0KVAC (20mA) Output-FG: 500VAC (100mA) for 1 min. Isolation Resistance: More than 100 MΩ at Ta=25 ℃ and 70 % RH , Output-FG:500 VDC Vibration: At no operating, 10-55Hz (sweep for 1 mnt) 19.6m/s² Safety: Approved by UL60950, CSA60950, EN60950, EN50178 EMI (*1): Built to meet FCC-Class B, EN 55011/EN 55022-B Immunity (*1): Built to meet EN61000-4-2,-3,-4,-5,-6,-8,-11 Weight (Typ): 400 G Dimension: 37x92x159 (Refer to Outline Drawing) *Read instruction manual carefully, before using the power supply unit. =Notes = *1: At maximum output power , nominal output voltage , Ta = 25 °C *2: For case when conformance to various safety specs ( UL,CSA,EN) are required, to be described as 100-240 VAC , 50 /60Hz on name plate. *3: Please refer to Output Derating Curve for input voltage less than 100-240 VAC (next page). *4: Not applicable for the in-rush current to noise filter for less than 0.2 ms. *5: Please to Fig A for measurement of line and load regulation, ripple and noise voltage . Ripple and Noise are measured at 20MHz by using at 12" twisted pair terminated with a 0.1uF and a 47uF capacitor . *6: 85-265VAC,constant load . *7: No load-Full load (Maximum power ), constant input voltage . *8: Current limiting with automatic recovery .Avoid to operate at overload or dead short for more than 30 seconds *9: OVD circuit will shut down output, manual reset (Re power on) *10: Measuring by each measuring method of UL, CSA, EN. *11: Refer to Output Derating Curve (next page) for details of output derating versus ambient temperature and mounting method.