Hantek DSO2C10 Digital Oscilloscope 2CH Digital Storage

Hantek DSO2C10 Digital Oscilloscope 2CH Digital Storage

$272.79
{{option.name}}: {{selected_options[option.position]}}
{{value_obj.value}}

Features: 1), 2 channels, each channel has independent knob control; 2), Analog bandwidth 100MHZ 3) The highest sampling rate is 1 GSa/s; 4), The storage depth is 8Mpts; 5), The vertical range of 2mV/div ~ 10V/div; 6) Vertical resolution: 8bit; 7) Trigger: edge, pulse, video, slope, timeout, window, pattern, interval, runt, UART, LIN, CAN, SPI, IIC; 8) Bus decoding and protocol analysis: RS232/UART, I2C, SPI, CAN, LIN; 9), Can save settings, waveforms, reference waveforms, CSV, pictures and other data formats. 10), 3-digit digital voltmeter and 6-digit frequency meter functions; 11) Support 32 kinds of automatic measurement and statistics functions, real-time statistics of minimum, maximum, standard deviation and other statistical information; 12), Two groups of digital voltmeter functions; 13) Support threshold test to realize free measurement in the screen; 14), Rich SCPI remote control instructions; 15). Provide multiple types of peripheral interfaces: USB Host/Device. Product Model(NOTE:Click on the model to reach the purchase link of the corresponding model): Model           Channels Bandwidth Sampling Rate Storage Depth Signal Source (AWG) >>DSO2C10<< 2CH 100MHz 1GSa/S 8M / >>DSO2C15<< 2CH 150MHz 1GSa/S 8M / >>DSO2D10<< 2CH 1CH 100MHz 1GSa/S 8M 1CH >>DSO2D15<< 2CH 1CH 150MHz 1GSa/S 8M 1CH Specification: model DSO2D15 DSO2D10 DSO2C15 DSO2C10 bandwidth 150MHz 100MHz 150MHz 100MHz Number of oscilloscope channels 2CH 2CH 2CH 2CH Built-in signal source 1CH 1CH  -  - Oscilloscope index Sampling rate range 1GSa/s (single channel), 500MSa/s (dual channel) Collection method sampling Sample data Peak-to-peak Display high frequency and random glitches average value Average waveform, times: 4, 8, 16, 32, 64, 128 High precision Up to 12bit enter Input coupling DC, AC or ground (DC, AC, GND) input resistance 1MΩ±2% ‖20pF±3pF Probe attenuation coefficient setting 1X, 10X, 100X, 1000X Voltage level 300V CAT II Maximum input voltage 300VRMS (10X) Horizontal system Waveform interpolation (sin x)/x Maximum record length Maximum 8M per channel Maximum 4M for dual channels Horizontal scale range 2ns/div~100s/div 1, 2, 5 steps Time base mode YT, XY, Roll  Zero offsets ±0.5 div×minimum time base gear Sampling rate and delay time accuracy ±50ppm Clock drift ≤±5 ppm/year Incremental time measurement accuracy Single, "sampled" mode (Full bandwidth) ±(1 sampling interval 100ppm×reading 0.6ns) >16 times above average ±(1 sampling interval 100ppm×reading 0.4ns) Sampling interval = second/div÷200 Vertical system model DSO2D15 DSO2D10 DSO2C15 DSO2C10 bandwidth 150MHz 100MHz 150MHz 100MHz Rise time at BNC (typical) 2.3ns 3.5ns 2.3ns 3.5ns Vertical resolution 8-bit resolution, simultaneous sampling for each channel Vertical sensitivity 2mV/div to 10V/div Offsets range 2mV/div to 20mV/div, ±100mV; 50mV/div to 200mV/div, ±1V; 500mV / div to 2V / cell, ± 10V; 5V / div to 10V / division, ± 50V computation Add, subtract, multiply, divide, FFT FFT Window: Rectangular, Hanning, Hamming, Brackman, Bartlett, flat top window Bandwidth limit 20MHz Low frequency response (-3db) ≤10Hz at BNC Vertical gain accuracy In the "sample" or "average" acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%; In "Sampling" or "Average" acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4% DC offsets accuracy ±0.1 div±2 mV±1% offsets value Voltage measurement repeatability, average acquisition mode Under the same settings and environmental conditions, the voltage increment between any two sets of average values ​​of more than 16 waveforms: ±(3%×reading 0.05 division) Note: The bandwidth is reduced to 6MHz when using X1 probe Trigger system Trigger type Edge, pulse, video, slope, timeout, window, pattern, interval, runt, UART, LIN, CAN, SPI, IIC Trigger level range  ±5 divisions from the center of the screen Trigger mode Automatic, normal, single Level CH1~CH2 ±4 divisions from the center of the display EXT 0~3.3V Range of relief 8ns~10s Trigger level accuracy CH1~CH2 0.2 divisions × volts/div within ±4 divisions from the center display EXT ±(6% 40mV of setting value) Edge Trigger Slope Rising edge, falling edge, rising edge or falling edge Source CH1, CH2, EXT Pulse width trigger polarity Positive polarity, negative polarity Condition (When) <, >, !=, = Source CH1~CH2, Pulse width range 8ns ~ 10s Precision 8ns Video trigger Signal standard NTSC, PAL Source CH1~CH2 Synchronize Scan line, line number, odd field, even field, all field Slope trigger Slope Rise and fall Condition (When) <,>, !=, = Source CH1 ~ CH2 time limit 8ns ~ 10s Precision 8ns Timeout trigger Source CH1~CH2, polarity Positive polarity, negative polarity time limit 8ns ~ 10s Precision 8ns Window trigger Source CH1~CH2  Pattern trigger Pattern 0: low level; 1: high level; X: ignore; :rising; :falling; :rising or falling Level (source) CH1~CH2 Interval trigger Slope Rise and fall Condition (When) <,>, !=, = Source CH1~CH2, time limit 8ns ~ 10s Precision 8ns Runt trigger polarity Positive polarity, negative polarity Condition (When) <,>, !=, = Source CH1~CH2 time limit 8ns ~ 10s Precision 8ns UART trigger Condition (When) Start, stop, data, parity, receive error Source (RX/TX) CH1~CH2  Data Format Hex (hexadecimal) Data length 1 byte Data bit width 5 bit, 6 bit, 7 bit, 8 bit Parity check None, odd, even Idle level High, low Baud rate (optional) 110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s Baud rate (custom) 300bit/s~334000bit/s LIN trigger Condition (When) Interval field, sync field, ID field, sync error, identifier, ID and data Source CH1~CH2, Data Format Hex (hexadecimal) Baud rate (optional) 110/300/600/1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/380400/460400 bit/s Baud rate (custom) 300bit/s~334000bit/s CAN trigger Condition (When) Start bit, remote frame ID, data frame ID, frame ID, remote frame data, data frame data, error frame, all errors, response error, overload frame Source CH1~CH2 Data Format Hex (hexadecimal) Baud rate (optional) 10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000 Baud rate (custom) 5kbit/s~1Mbit/s   SPI trigger Source CH1~CH2, Data Format Hex (hexadecimal) Data bit width 4, 8, 16, 24, 32 IIC trigger Source (SDA/SCL) CH1~CH2, Data Format Hex (hexadecimal)          Data index 0~7 Timing (condition) Start bits, stop bits, no answer, address, data, reboot measuring cursor Voltage difference between cursors△V Time difference between cursors△T The reciprocal of △T, in Hertz (1/△T) Automatic measurement Frequency, period, average value, peak-to-peak value, root mean square, minimum value, maximum value, rise time, fall time, positive pulse width, negative pulse width, bottom value, top value, middle value, amplitude, overshoot , Preshoot, rising edge phase difference, falling edge phase difference, positive duty cycle, negative duty cycle, cycle average, cycle root mean square, falling edge overshoot, rising edge preshoot, BWIDTH, FRF, FFR, LRR , LRF, LFR, LFF DVM data source CH1, CH2 Measurement type DC effective value AC effective value Direct current frequency meter Hardware 6-digit frequency counter Signal source indicator Number of channels 1 channel Sampling Rate 200MSa/s Vertical resolution 12 bits  Highest frequency 25 MHz  Standard waveform Sine, square wave, pulse, triangle wave, sampling wave, exponential wave, noise Arbitrary waveform Arb1, Arb2, Arb3, Arb4 Sine Frequency Range 0.1Hz~25MHz Square wave/pulse Frequency Range 0.1Hz ~ 10MHz Triangle wave Frequency Range 0.1Hz~1MHz Sample wave Frequency Range 0.1Hz~1MHz Exponential wave Frequency Range 0.1Hz~5MHz noise   Arbitrary Wave 1 Frequency Range 0.1 Hz to 10 MHz  Arbitrary Wave 2 Frequency Range 0.1 Hz to 10 MHz  Arbitrary Wave 3 Frequency Range 0.1 Hz to 10 MHz  Arbitrary Wave 4 Frequency Range 0.1 Hz to 10 MHz  Wave length 8KSa frequency Precision 100 ppm (less than 10 kHz) 50 ppm (greater than 10 kHz) Resolution 0.1 Hz or 4 bits, whichever is greater Amplitude Output range 10mV~7Vp-p (high impedance) 5mV~3.5Vp-p(50Ω) DC offsets range ±3.5 V, high resistance ±1.75 V, 50 Ω Resolution 100 μV or 3 bits, whichever is greater Precision 2% (1 kHz) Output impedance 50 Ω General technical specifications display Display type 7" TFT LCD display diagonally Display resolution 800 (horizontal) * 480 (vertical) pixels Display color 16 million colors (24 bit true color) Afterglow time Minimum value, 1 s, 5 s, 10 s, 30S, unlimited Display type Point, vector Display brightness Adjustable Grid type Optional Grid brightness Adjustable interface Standard interface USB Host, USB Device General technical specifications Probe compensator output Output voltage, typical About 2Vpp input ≥1MΩ load Frequency, typical 1kHz voltage 100-120VAC RMS (±10%), 45Hz to 440Hz, CATⅡ 120-240VAC RMS (±10%), 45Hz to 66Hz, CATⅡ Power consumption Less than 30W Fuse T, 3.15A, 250V, 5x20mm Operating temperature 0~50 °C (32~122 °F) storage temperature -40~ 71 °C (-40~159.8 °F) humidity ≤ 104℉(≤ 40°C): ≤90% relative humidity 106℉~122℉ ( 41°C ~50°C): ≤60% relative humidity Altitude When operating and not operating 3,000m (10,000 feet) Mechanical shock Random vibration 0.31g RMS from 50Hz to 500Hz , 10 minutes per axis When not operating 2.46g RMS from 5Hz to 500Hz , 10 minutes per axis During operation 50g, 11ms, half sine wave Mechanical part Oscilloscope size 318 x 140 x 150mm (length x width x height) weight 2900g   Package includes: 1 X Hantek DSO2C10 Digital Oscilloscope Details pictures: 

Show More Show Less