Bijur - L5H Pump (1 Outlet) - D3274C
L5H 1P SLR 1OUTLET Technical Data Lubricant OIL Viscosity Range 150-8000 SSU Reservoir 1P Outlet Thread 5/16-24 OUTPUT VOLUME 1-5cc Max Pressure PSI 75 Max Pressure Bar 5 Fill FILL CAP UM EA Lubricator Inlet Filter 40 micron L5H Lubricator Manual, One Shot, Pull Type Operation Lubricator includes a spring return piston pump. When the tee-handle is fully raised, a predetermined volume of oil fills the cylinder and the pump spring is compressed. Releasing the handle forces oil into the distribution system. Lubricator will deliver 5cc per stroke of the piston. The lubricator should be operated at intervals recommended by the machine manufacturer. Startup Instructions Fill reservoir; operate lubricator until oil flows freely at all bearings. Maintenance Filter Replacement A filter at pump inlet protects the lubricating system and should be inspected every six months. If not clean, replace. To remove filter, pry out snap ring with screwdriver and r