
2000 Series Railroad Test Analog Meters for Passenger and Commercial Rails: 60Hz - 250Hz Cabin Filters (2010-2013)
The 2000 Series Railroad Testers are designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment. Read More > DESCRIPTION The 2000 Series Railroad Testers are designed to perform standard maintenance tasks (using Volts, Ohms, and Amps measurements) as well as specialized tasks requiring measurements on railroad coding equipment. The 2000 Series is compatible with older test technologies and offers test features not found on earlier test sets.2010/2011/2012/2013-NIST Comes with Certificate of traceability to NIST standards Please add 11 business days lead-time for the NIST calibration process CATEGORY: RAILROAD TEST SETS Features Base unit with no Cab Filters Auto Polarity in DC functions Both Auto and Selectable DC Amps Polarity Direct measurement of Code Parameters Ohmmeter Voltage Mode detects foreign AC or DC Voltages Relay Contact On Time (Dry Contact) requires no adjustment Peak measurements require no adjustment Lead time for NIST Certified products is 5-7 business days Upon order placement, please provide the company name that should appear on the certificate. Without this information, we will not be able to provide a certificate of calibration. Product Overview Fewer jacks, more ranges, and a logical front panel layout all contribute to the 2000 Series' ease of use. A precision multi-turn Ohms Adjust Control facilitates accurate resistance measurements. Also, the measurement of relay contact On Time has been simplified and expanded requiring no adjustments. Code Parameter measurements have been made simpler and more accurate. It is no longer necessary to count pointer swings to measure On Time. It can be measured on live signals as well as relay contacts. Peak Levels can be determined quickly and automatically, and adjustments to the code equipment peak level can be made without constantly readjusting the Test Set. Some models offer Cab filters, allowing measurement of the individual Cab Signal carrier frequencies, whether coded or un-coded. All 2000 Series Railroad Testers include: test leads, padded water repellent carrying case, shoulder Strap, and batteries. Specifications Specifications Model 2000 Model 2001 Model 2002 Model 2003 DC Voltage 0.6V, 3V, 15V, 60V, 300V 0.6V, 3V, 15V, 60V, 300V 0.6V, 3V, 15V, 60V, 300V 0.6V, 3V, 15V, 60V, 300V DCV Accuracy ±1.5% FS ±1.5% FS ±1.5% FS ±1.5% FS DC Milliamps 16mA, 60mA, 300mA 16mA, 60mA, 300mA 16mA, 60mA, 300mA 16mA, 60mA, 300mA DC mA Accuracy ±1.5% FS ±1.5% FS ±1.5% FS ±1.5% FS DC Amps 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A DCA Accuracy ±1.5% FS ±1.5% FS ±1.5% FS ±1.5% FS AC Voltage 1.5V, 3V, 15V, 150V, 300V, 600V 1.5V, 3V, 15V, 150V, 300V, 600V 1.5V, 3V, 15V, 150V, 300V, 600V 1.5V, 3V, 15V, 150V, 300V, 600V ACV Accuracy ±3.0% FS ±3.0% FS ±3.0% FS ±3.0% FS AC Amps 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A 1.5A, 6A, 30A ACA Accuracy ±3.0% FS ±3.0% FS ±3.0% FS ±3.0% FS Cab Filter Response(All AC ranges) 60Hz: —100Hz: —200Hz: —250Hz: — 60Hz: —100Hz: 92 to 100Hz200Hz: —250Hz: 245 to 255Hz 60Hz: —100Hz: 92 to 100Hz200Hz: 196 to 204Hz250Hz: — 60Hz: 57 to 63Hz100Hz: 92 to 100Hz200Hz: —250Hz: — Code Functions(All AC and DC Ranges) On Time: 3% to 100% (±3% FS)Rate: 30 to 500CPM (±3% FS)Peak Hold: ÖPeak Follow: Ö On Time: 3% to 100% (±3% FS)Rate: 30 to 500CPM (±3% FS)Peak Hold: ÖPeak Follow: Ö On Time: 3% to 100% (±3% FS)Rate: 30 to 500CPM (±3% FS)Peak Hold: ÖPeak Follow: Ö On Time: 3% to 100% (±3% FS)Rate: 30 to 500CPM (±3% FS)Peak Hold: ÖPeak Follow: Ö Volt Senese Mode 15V AC or DC (±20%) 15V AC or DC (±20%) 15V AC or DC (±20%) 15V AC or DC (±20%) Resistance Range: R x 1 and R x 100Center Scale: 5 and 500 ohmsAccuracy: ±2% of scale length Range: R x 1 and R x 100Center Scale: 5 and 500 ohmsAccuracy: ±2% of scale length Range: R x 1 and R x 100Center Scale: 5 and 500 ohmsAccuracy: ±2% of scale length Range: R x 1 and R x 100Center Scale: 5 and 500 ohmsAccuracy: ±2% of scale length Dry Contact Allowable Resistance: 0 to 100 ohmsTest Voltage: 7.5 to 15VDCTest Current: less than 1mA Allowable Resistance: 0 to 100 ohmsTest Voltage: 7.5 to 15VDCTest Current: less than 1mA Allowable Resistance: 0 to 100 ohmsTest Voltage: 7.5 to 15VDCTest Current: less than 1mA Allowable Resistance: 0 to 100 ohmsTest Voltage: 7.5 to 15VDCTest Current: less than 1mA Power (2) 9V; (1) 1.5V D cell Dimensions 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) 5 x 6.5 x 3.2" (127 x 165.1 x 81.3mm) Weight 4.75 lbs (2.15kg) with case and leads 4.75 lbs (2.15kg) with case and leads 4.75 lbs (2.15kg) with case and leads 4.75 lbs (2.15kg) with case and leads Downloads DatasheetUser ManualBrochureBrochure - En Espanol VIDEO