VTSYIQI Foundation Pile Monitor Project Pile Reflected Wave Method for Assess The Integrality of Concrete Pile and Identify Wireless
VTSYIQI Foundation Pile Monitor Project Pile Reflected Wave Method for Assess The Integrality of Concrete Pile and Identify Wireless About this item ◆ Wireless connectivity between accelerated sensor and PDA allows easy and more flexible usage on site. PDA can work up to 10 meters away from the accelerated sensor ◆Real time on-site processing such as smoothing, differential, filtering, exponent and linear amplification can be given to tested waveform ◆The signal noise can be eliminated by taking average superposition of multiple signals. Superposition signals can be checked at any time, and poor-quality signals can be rejected , New wavelet processing method can effectively judge the integrity of foundation pile in complex situation ◆Project/pile testing data can be easily saved, accessed, edited, or deleted , Intelligent sensor can complete the acquisition work, and upload the data to the computer through the Wi-Fi, get rid of signal wire entanglement, efficient, fast and smooth ◆Gain value can be adjusted according to length of pile and top surface condition of pile , True 24 bit A/D data acquisition makes test waveform more real, avoiding the noise and signal distortion caused by floating point amplification Field of useBy using the reflected wave method, the device is used to assess the integrity of concrete pile and identify the extent and location of the pile defect. It can be used for testing bored concrete pile and hammer pile.It can also be used for testing the constructions with an exposed top surface such as pillars.specificationModel :ZBL-P8000Control Mode : Android platformScreen : High brightness, TFT color LCD screenData Storage : ≥8GBOperation Mode : touch screenSentinel magnify (time): 1、2、4、8、16、32 adjustableA/D resolution (bit) : 24 bits A/DSampling time intervals(μs) : 6.4~1638.4 adjustableMax length of sampling :≥2048Trigger :Signal triggerNoise voltage of the system (mV): ≤2Dynamic range(dB) :≥180Amplifier frequency range(Hz) : 1~10kMax storage length :2048Amplitude nonlinear degree :≤10%Fixed point magnification :1, 2, 4, 8, 16, 32,64Error of time indication: ≤1%Time resolution(us) : 6.4Gain error(dB) : ≤1Continuous working time(h) :>5Number of channels : 1Interference between the channels :noTransducer/Probe Sensitivity(acceleration mode)(mv/g)::≥100Frequency range of Probe(Acceleration probe) (Hz):0.5 ~ 9000PowerInternal : Built-in-batteryExternal : 220V AC/DCWi-fi : yesWeight(kg) : 0.34kg(lithium battery included)Total volume(mm) :φ5×120