Ultrasonic flow meter
Description of Sensor Functions Adjusting the switching points and the analog output. The switch output type and analog output type sensor can be programed as the user want. There are 8 types of output functions can be programed. All the teach routine as follows, step 1 teach one point with the related teach in condition (High level voltage or GND). step 2 choose a different distance (not the same with step1) point and a different teach in condition (not same with the step1). The program routine must be finished during the blue led flashing; the default value will be efficient if the not. The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. Switching point A1 is taught with - UB, A2 with +UB. Five different output