
Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
Model: Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex Part Number: 376 FC Ordering Number: 1C7459 The Fluke 376 FC is part of the Fluke Connect family of wireless test tools. Now you can: Log and trend measurements to pinpoint intermittent faults Transmit results wirelessly via Fluke Connect® Measurements app Create and send reports right from the field Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices The Fluke 376 FC is the direct replacement for the Fluke 376 Clamp Meter. Includes: 18-inch iFlex® Flexible Current Probe TPAK magnetic hanging strap Soft carrying case TL75 test leads Two AA Alkaline batteries Coated instruction card Safety information sheet Features Connect your meter to your smartphone with Fluke Connect Measurements Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks Record results directly to your phone and the Cloud Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included) TPAK magnetic hanging strap (included) Integrated VFD low pass filter for accurate motor drive measurements Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it CAT IV 600 V, CAT III 1000 V safety rating Three-year warranty Soft carrying case Measurement Capability 1000 A ac and dc current measurement 2500 A ac current measurement with iFlex flexible current probe 1000 V ac and dc voltage measurement True-rms voltage and current for accurate measurements on non-linear signals Frequency measurement to 500 Hz with body jaw and iFlex Resistance measurement to 60 kΩ with continuity detection Min, max, average, and inrush recording to capture variations automatically 500 mV dc measurement range to interface with other accessories 1000 μF capacitance measurement General Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) Crest Factor (50 Hz/60 Hz) 3 @ 500 A 2.5 @ 600 A Add 2% for C.F. >2 Flexible Current Probe AC Current via Flexible Current Probe Range 2500 A Resolution 0.1 A (≤ 600 A) 1 A (≤ 2500 A) Accuracy 3% ±5 digits (5 – 500 Hz) Crest Factor (50/60Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Frequency via Flexible Current Probe Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Position Sensitivity i2500-10 Flex i2500-18 Flex A Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm) Error ±0.5 % ±0.5 % B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm) Error ±1.0 % ±1.0 % C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm) Error ±2.0 % ±2.0 % Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. Specifications DC Current Range 600.0 A Resolution 0.1 A Accuracy 2% ±5 digits AC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1.5% ±5 digits (20 Hz to 500 Hz) DC Voltage Range 1000 V Resolution 0.1 V (≤600.0 V) 1 V (≤1000 V) Accuracy 1% ±5 digits mV dc Range 500.0 mV Resolution 0.1 mV Accuracy 1% ±5 digits Frequency via Jaw Range 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ±5 digits Trigger level 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A Resistance Range 60 kΩ Resolution 0.1 Ω (≤600 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60 kΩ) Accuracy 1% ±5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ±4 digits Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V Batteries 2 AA, NEDA 15A, IEC LR6 Operating temperature -10 °C to +50 °C Storage temperature -40 °C to +60 °C Operating humidity -non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C) ≤75% RH (at 30 °C to 40 °C) ≤45% RH (at 40 °C to 50 °C) Operating altitude 3000 m Storage altitude 12,000 m Size (L x W x H) 249 x 85 x 45 mm Weight 395 g Jaw opening 34 mm Flexible current probe diameter 7.5 mm Flexible current probe cable length(head to electronics connector) 1.8 m Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V IP rating IEC 60529: IP30, non-operating Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.