
CONTEC MS200
Experience precise NIBP monitor testing with the streamlined, user-friendly CONTEC MS200 Simulator. It utilizes an Oscillometer to generate up to 400mmHg (53.3 kPa) of pressure, and offers dynamic BP simulation, static pressure calibration, automatic leak testing, and over-pressure relief testing for efficient and accurate analysis.Functions 1) Pressure leak test 2) Over-pressure relief test 3) BP simulation under standard condition 4) BP simulation under patient condition 5) BP simulation under arrhythmia condition 6) BP simulation under respiratory interference condition 7) BP simulation of neonate 8) Wrist BP simulation 9) User-defined BP simulation 10) System setting function. 11) The parameters set can be stored. 12) ON/OFF function 13) Dynamic BP simulation Performance Systolic pressure: 2.7 kPa (20 mmHg) ~ 40.0 kPa (300 mmHg) Diastolic pressure: 1.3kPa (10 mmHg) ~ 33.3 kPa (250mmHg) Pulse volume: 0.1 cc ~ 2.4 cc HR range: 30 bpm ~ 250 bpm; pulse volume > 2.00 cc, maximum HR: 200 bpm HR accuracy: ± 1 bpm (except patient condition, arrhythmia and respiratory disturbance) Under patient condition: Weak pulse, tachycardia, obese, geriatric: ±(preset value 1%+1)bpm Moderate exercise: ±(preset value 1.5%+1)bpm Strenuous exercise: ±(preset value 3%+1)bpm Pressure measurement: Range: 0kPa (0 mmHg) ~ 53.3 kPa (400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Accuracy: 0 kPa (0 mmHg) ~ 40.0 kPa (300 mmHg), ± (0.5 % of reading + 0.1) kPa or ± (0.5% of reading +1) mmHg 40.1 kPa (301 mmHg) ~ 53.3 kPa (400mmHg), ± 2% of reading Pressure leak test Generate a pressure up to 400 mmHg by the built-in air pump. It always displays the peak pressure and the real-time pressure. Leak rate is displayed after 10 seconds. Over-pressure relief test Generate a pressure up to 400 mmHg by the built-in air pump, it displays peak pressure. Pressure source: Output range: 6.7 kPa (50 mmHg) ~ 53.3 kPa(400 mmHg) Resolution: 0.1 kPa, 1 mmHg, 1 cmH2O, 1 inH2O, 0.1 psi Deviation between target pressure and actual pressure: ± 1.3 kPa (± 10 mmHg) in range of 13.3 kPa (100 mmHg) ~ 53.3 kPa (400 mmHg) with a minimum volume of 300 cc Airtightness Total airtightness: < 0.3 kPa/min (2.25 mmHg/min) under “OFF” state Accessories One User Manual Two fuses One power cordPhysical CharacteristicsDisplay: 4.3" 65 K color LCD display Power supply: AC100 ~ 240 V 50/60 Hz, <60 VA Environment temperature: + 5 ℃ ~ + 40 ℃ Relative humidity: < 90 %, non-condensing Altitude: ≤ 3000 m Atmospheric pressure: 80 kPa ~ 106 kPa Dimension: 207 (L) × 220 (W) × 121 (H) mm Weight: about 2.1 kg