Ai 10°C to 25°C 33L/Min 35L Capacity Recirculating Chiller

Ai 10°C to 25°C 33L/Min 35L Capacity Recirculating Chiller

$8,395.74

Digital temperature controlled recirculating water chiller with built-in swivel casters, recommended for our IH series induction heaters (see models below). These chillers have built-in stainless steel tank, water pump and tubing for durability and rust-free operations. Water manifold included for immediate use. Specifications Specifications   Model  WAC-4  Controller  Digital micro-chip controlled with LCD screen and fluid level display  Input power  480VAC 60Hz three-phase (3PH) 3.75kW  Nominal cooling capacity  10366 kcal per hour  Nominal cooling capacity is according to:        Inlet chilled fluid temperature: 12°C        Outlet chilled fluid temperature: 7°C        Inlet cooling air temperature: 30°C        Outlet cooling air temperature: 35°C  Compressor  Make: Danfoss (UL Listed) Power: 460V 3-60Hz 8A 3750 watts, LR 25A, thermally protected Refrigerant: R407C (2,400g) PS: 22.6 bar, TS max: 50°C, TS min: -35°C Number of compressors installed: one  Water pump  Make: LX (CMF2-50T-A-W-G-BABE) Power: 480V 60Hz 3-PH 550 watts 2.5/Y1.4A 3450 rpm IP55 Max liquid temperature: 70°C Pumping speed: 33L per minute Max pressure: 10 bar. H(max): 64m, H(n): 51m  Reservoir capacity  35L  Recommended coolant  Distilled water  Cooling fan  Make: Weiguang (YWF4D-350S-102/34-G) Power: 480V 60Hz 80/150 watts 0.27A 1640 rpm Number of fans installed: two Flow rate: 142,000 cu ft per hour  Temperature accuracy  +/- 2 °C  Water inlet & outlet on chiller  1.5" inch Tri-Clamp  Water manifold  Inlet: 1.5” inch Tri-clamp, manifold: one 1” inch, two 8mm quick connect with ball valve  Unit/shipping weight  375 Lb / 485 Lb  Unit/shipping dimensions  41 x 22 x 54" / 50 x 25 x 61" (DxWxH)  Safety  Over current, compressor delay start, water pump over load, built-in fuse, over-voltage and under- voltage, abnormal operations, phase protection and  Working environment  Temperature range of chilled fluid: 5°C - 35°C. Temperature  difference of chilled fluid between inlet and outlet: 3°C - 8°C.  It is better to use the chiller while the ambient temperature is at or below 35°C  Recommended to use with these induction heaters  (result may vary on different applications)  High frequency 10kW, 20kW, 30kW Mid frequency 25kW, 35kW Low frequency 25kW, 35kW  CE compliant  Yes  Warrenty   One Year Standard Packages Standard package Item Quantity Image  WAC-4 recirculating chiller  1 pc  Water manifold 2 pcs    KF40 flange 2 pcs    Users manual 1 pc  

Show More Show Less